+86 18068001229 01
Cov Chaw Nres Tsheb Me Me Uas Muaj Peev Xwm Loj Hlob Tau Rau Kev Siv Hauv Kev Lag Luam
Cov Nta Tseem Ceeb & Cov Txiaj Ntsig
Tsim Kom Siv Tau Qhov Chaw Zoo
Cov qauv modular txo qhov loj ntawm lub cev mus txog 60% piv rau cov chaw hloov hluav taws xob ib txwm muaj, ua rau kev teeb tsa ua tau hauv cov chaw txwv xws li txoj kev hauv nroog, cov chaw tsim khoom lag luam, lossis cov zej zog nyob deb. Cov chav sib dhos ua ntej txo lub sijhawm tsim kho hauv qhov chaw.
Kev Ua Haujlwm Zoo & Kev Ntseeg Siab
Nruab nrog cov roj-immersed lossis qhuav-hom transformers, vacuum circuit breakers, thiab SF6 gas-insulated switchgear (GIS), cov chaw hloov pauv no ua kom muaj kev tswj hwm hluav taws xob zoo (11kV txog 33kV) thiab kev tiv thaiv kev ua yuam kev. Cov rwb thaiv tsev thiab cov tshuab cua txias ruaj khov ua rau muaj kev ruaj khov hauv huab cua hnyav.
Kev Tswj Xyuas thiab Kev Saib Xyuas Ntse
Cov tshuab IoT uas xaiv tau muab cov ntaub ntawv tiag tiag ntawm qhov hluav taws xob, tam sim no, kub, thiab kev kuaj pom qhov txhaum. Cov peev xwm tswj hwm chaw taws teeb ntawm SCADA sib koom ua ke nrog cov tes hauj lwm ntse, ua rau muaj kev saib xyuas ua ntej thiab txo lub sijhawm tsis ua haujlwm.
Kev Xa Tawm Sai & Kev Loj Hlob Tau
Cov chav tsev uas tau sib dhos thiab kuaj los ntawm lub Hoobkas tuaj yeem teeb tsa tau hauv ob peb hnub, ua kom lub sijhawm ua haujlwm sai dua. Cov qauv tsim uas nthuav dav tau tso cai rau kev txhim kho lub peev xwm (txog li 50 MVA) yam tsis tas hloov tag nrho lub kaw lus, txhawb kev loj hlob ntawm lub zog mus sij hawm ntev.
Eco-Friendly & Pheej Yig
Kev ua haujlwm suab nrov qis (




Cov ntawv thov
Kev Tsim Kho Hauv nroog: Cov chaw hloov hluav taws xob rau cov cheeb tsam hauv nroog, cov chaw lag luam, thiab cov nroog ntse.
Cov Cheeb Tsam Kev Lag Luam: Kev muab hluav taws xob ruaj khov rau cov chaw tsim khoom, cov chaw tsuas, thiab cov chaw khaws ntaub ntawv.
Cov Cheeb Tsam Nyob Deb: Kev xa tawm sai hauv cov cheeb tsam uas tsis muaj hluav taws xob lossis muaj kev puas tsuaj.
Lub zog rov ua dua tshiab: Kev koom ua ke nrog cov liaj teb hnub ci / cua rau kev sib txuas hluav taws xob zoo.
Cov Lus Qhia Txog Kev Siv
Qhov Voltage Ntau: 11kV txog 33kV (qhov hluav taws xob nruab nrab).
Peev Xwm: 5 VAT txog 50 VAT.
Zaus: 50Hz/60Hz.
Txias: Cua txias ntuj (AN) lossis yuam (AF) txias.
Kev Ua Raws Cai: Tau ntawv pov thawj los ntawm IEC 62271, IEEE 1526, thiab ISO 9001/14001.
Kev Tswj Xyuas Zoo
Kev ntsuam xyuas nruj suav nrog lub zog dielectric, kev tiv taus luv luv, thiab kev ua qauv qhia txog qhov kub thiab txias nce.
Tau ntawv pov thawj los ntawm KEMA, DEKRA, thiab TÜV rau kev nyab xeeb thiab kev ntseeg tau.
Vim li cas ho xaiv peb?
25+ Xyoo ntawm Kev Paub: Cov qauv tsim tau ua pov thawj rau qhov kub thiab txias heev, av noo, thiab thaj chaw seismic.
Cov Kev Pabcuam Xaus-rau-Xaus: Kev tsim qauv, kev teeb tsa, thiab kev txhawb nqa kev saib xyuas lub neej tas mus li.
Kev Nyiaj Txiag Yooj Yim: Kev xaiv xauj tsev thiab them nyiaj raws li koj siv tau rau kev ywj pheej ntawm peev nyiaj.
Kev daws teeb meem tshwj xeeb
Kev Hloov Kho Ib puag ncig: Cov ntaub thaiv uas tiv taus xeb rau cov cheeb tsam ntug dej hiav txwv lossis cov qauv tsim uas tiv taus tawg rau cov chaw roj/roj.
Cov Txheej Txheem Sib Xyaws: Kev koom ua ke ntawm kev khaws cia lub zog rov ua dua tshiab (piv txwv li, cov txhab roj teeb) rau cov hybrid grids.



Cov txiaj ntsig ntawm cov khoom
1. Cov Khoom Siv Tseem Ceeb thiab Kev Tsim Qauv Winding
Cov Khoom Siv Tseem Ceeb
Amorphous Alloy Cores:
Kev poob hlau tsawg heev (qis dua 70–80% piv rau cov hlau silicon) txo cov kev pov tseg hluav taws xob, qhov tseem ceeb rau cov qauv tsim me me, ua haujlwm tau zoo.
Kev nkag tau zoo thiab ze li ntawm xoom magnetostriction txo qhov suab nrov, zoo tagnrho rau thaj chaw hauv nroog lossis thaj chaw nyob.
Cov Hlau Silicon Uas Muaj Cov Nplej Uas Txias Thiab Dov Tau (CRGO):
Cov laminations txiav laser txo cov kev poob tam sim no, ua tiav cov theem ua haujlwm tau zoo txog li 98.5% hauv qhov chaw tsawg.
Qhov ceev ntawm cov hlau nplaum sib nqus siab txhawb nqa cov ntawv thov compact high-voltage (11kV–33kV).
Kev Tsim Qauv Winding
Cov Ntawv Nyiaj Uas Muaj Roj-Flow Txias:
Cov xov hlau tooj liab/aluminium txo cov dej xau thiab cov zog luv luv. Cov kav roj sib xyaw ua ke ua rau cov cua sov ploj mus hauv cov qauv kaw.
Cov khaubncaws sab nraud povtseg sib xyaw ua ke txo qhov kev ntxhov siab ntawm qhov hluav taws xob ntawm qhov tig, txhim kho kev tiv thaiv luv luv (txog li 50 kA asymmetrical faults).
Cov Hlau Litz Txheej Txheem:
Cov xov hlau Litz ntau txoj hlua txo cov teebmeem ntawm daim tawv nqaij thiab qhov sib ze, txo cov AC tsis kam rau kev ua haujlwm siab (piv txwv li, HVDC txuas).
Cov Kev Npaj Compact Disc/Winding:
Cov xov hlau helical lossis disc ua kom zoo dua qhov chaw siv, ua ke nrog cov rwb thaiv tsev kom tiv taus lub zog xob laim (≥1.2 / 50 μs).
2. Cov Txheej Txheem Rwb Thaiv Tsev
Kev rwb thaiv tsev roj-ntawv sib xyaw:
Daim ntawv cellulose uas muaj cov kua ester impregnated muab lub zog dielectric txog li 300 kV BIL, zoo tagnrho rau cov chaw me me uas muaj hluav taws xob siab.
Tiv taus kev hloov pauv kub (−40 ° C txog + 140 ° C) thiab kev tso tawm ib nrab.
Kev Ua Epoxy Resin Casting (Hom Qhuav):
Kev siv lub tshuab nqus tsev (VPI) nrog cov epoxy resins Class H ua kom muaj kev tiv thaiv hluav taws (IEC 60335) thiab kev tiv thaiv dej noo hauv cov chaw kaw.
Nano-Txhim Kho Kev Rwb Thaiv Tsev:
Cov khoom sib xyaw ua ke epoxy uas muaj silica txhim kho qhov tiv taus ib nrab ntawm kev tso tawm los ntawm 40%, ua rau lub neej ntev dua hauv cov nroog uas muaj av noo lossis muaj kuab paug.
3. Kev Tswj Xyuas Kub
Roj-Ntuj Cua Txias (ONAN):
Kev txias tsis siv neeg los ntawm cov radiators thiab cov cua sov ntuj rau kev ua haujlwm tas mus li hauv cov chaw me me (piv txwv li, 100kVA–500kVA units).
Kev Siv Cua Txias Yuam (OFAF):
Cov kiv cua tswj tau qhov kub thiab txias ua rau cov cua sov tawm tau zoo dua, ua rau muaj peev xwm ua haujlwm ntau dhau 120% rau cov xwm txheej ceev.
Kev Saib Xyuas Thermal Ntse:
Cov cuab yeej ntsuas fiber-optic taug qab cov hotspots, ua rau muaj kev ceeb toom lossis kev hloov kho txias kom tiv thaiv kev puas tsuaj ntawm cov rwb thaiv tsev.
4. Kev Tsim Qauv thiab Kev Tiv Thaiv
Kev Tsim Kho Modular thiab Chaw Zoo Tshaj Plaws
Cov Ntaub Ntawv Sib Txuas Ua Ke:
Cov thawv ntim khoom ua ntej, modular muaj cov transformers, switchgear, thiab cov tshuab tiv thaiv hauv ib qho chaw, txo lub sijhawm teeb tsa los ntawm 50%.
Kev Ntsuas IP66 / IP67:
Kev kaw ruaj khov nrog EPDM gaskets thiab cov khoom siv stainless-steel tiv thaiv dej, hmoov av, thiab nas nkag mus.
Kev kho mob tiv thaiv corrosion:
Cov hlau kub-dip galvanized lossis txhuas nrog polyurethane coatings tiv taus UV degradation thiab ntug dej hiav txwv ntsev.
Cov yam ntxwv kev nyab xeeb
Cov Li Qub Uas Pab Kom Lub Siab Rov Qab Zoo:
Yuav tso pa roj tawm thaum muaj teeb meem sab hauv, tiv thaiv kev tawg.
Cov Txheej Txheem ntawm Lub Tank Conservation:
Cov khoom siv kaw kaw txo cov pa oxygen, txo cov roj oxidation thiab cov av nkos.
Kev tiv thaiv hluav taws xob ntau dhau:
Cov khoom siv zinc oxide arresters (MOA) uas sib xyaw ua ke tiv thaiv cov teeb meem xob laim (≥2.5 kA impulses).
5. Cov Haujlwm Siab Tshaj Plaws
Cov Txheej Txheem Saib Xyuas Xwm Txheej (CMS):
Cov sensors uas muab tso rau hauv lub cev yuav taug qab qhov kub ntawm roj, kev tshuaj xyuas cov pa roj uas yaj (DGA), cov theem thauj khoom, thiab kev tso tawm ib nrab, ua rau muaj kev saib xyuas ua ntej los ntawm SCADA.
Kev Sib Koom Tes ntawm Smart Grid:
Kev sib txuas lus uas siv IoT txhawb nqa kev tswj chaw taws teeb, kev sib npaug ntawm qhov hnyav, thiab kev kho tus kheej ntawm lub grid.
Cov Kev Tsim Kho Tshiab Uas Zoo Rau Ib Puag Ncig:
Cov roj rwb thaiv tsev uas ua los ntawm cov khoom siv bio-based (piv txwv li, cov kua ester) uas muaj kev puas tsuaj ntau ntawm cov khoom siv biodegradable (ua raws li OECD 301B) thiab tsis yooj yim kub hnyiab.
Cov Ntawv Thov Tseem Ceeb thiab Cov Qauv Yav Tom Ntej
Kev faib tawm hauv nroog:
Cov chaw fais fab hauv nroog uas muaj cov chaw ceev fais fab ntau (500kVA–1 MVA), cov microgrids uas siv tau dua tshiab, thiab cov chaw them fais fab EV.
Kev Sib Koom Tes Zog Rov Ua Dua Tshiab:
Cov qauv tsim me me rau cov liaj teb cua/hnub ci thiab cov microgrids hybrid AC/DC.
Kev Nce Qib Yav Tom Ntej:
Cov Transformers Solid-State (SSTs): Pab kom muaj kev hloov pauv DC-DC thiab kev ywj pheej ntawm lub grid rau cov kab ke decentralized.
Kev Rwb Thaiv Kev Kho Tus Kheej: Cov ntaub ntawv Nanocomposite kho cov teeb meem me me ntawm dielectric.
Kev piav qhia luv luv
Cov Chaw Fais Fab Me Me zoo tshaj plaws los ntawm cov cores amorphous uas tsis tshua muaj kev poob qis, cov qauv tsim modular uas txuag chaw, thiab cov txheej txheem kev nyab xeeb ntau txheej. Lawv qhov kev sib xyaw ua ke ntawm kev ua haujlwm zoo, kev nthuav dav, thiab kev ywj pheej ua rau lawv tsis tseem ceeb rau cov nroog niaj hnub thiab cov lag luam, thaum cov kev tsim kho tshiab xws li cov thev naus laus zis solid-state thiab kev saib xyuas ntse tsav cov kev txawj ntse ntawm lub network thiab kev ruaj khov.



Nug Tam Sim No!
Yog tias koj muaj lus nug txog peb cov khoom lossis daim ntawv teev nqi, thov tawm koj tus email rau peb thiab peb yuav tiv tauj koj tsis pub dhau 24 teev.







