Ib Theem Ib Lub Transformer Mounted Ncej—15KVA

Kev Ntsuas Hluav Taws Xob Thawj Zaug: 12470 Delta V
Kev Ntsuas Hluav Taws Xob Thib Ob: 120/240V
HV KAW QHIA: ±2*2.5%
HOM KEV TXUAS: Ii6
HOM: Transformer ntsia rau ntawm ncej
YOG: 95/30kV
Cov Qauv: IEEE C57.12.20, ANSI C57.12
Daim Ntawv Thov: Kev faib tawm thiab kev faib tawm

    Kev piav qhia txog khoom

    JZP Transformer tshwj xeeb hauv kev tsim cov transformers 15 kVA ib theem uas tau teeb tsa los ntawm ncej uas ua raws li cov qauv thoob ntiaj teb, suav nrog IEEE C57.12.00, IEEE C57.12.20, DOE-2016 Efficiency Requirements, CSA C2.1 & C2.2, thiab CSA C802.1. Peb ua raws li kev cog lus rau kev ua tau zoo tshaj plaws, thiab peb muab cov kev daws teeb meem uas tsim los kom haum rau koj cov kev qhia tshwj xeeb.
    Txawm koj xav tau qib voltage lossis qhov chaw ua haujlwm li cas los xij, ntseeg JZP Transformer los muab cov kev daws teeb meem zoo tshaj plaws rau koj cov kev xav tau tshwj xeeb. Koj qhov kev txaus siab, ua ke nrog kev ntseeg siab ntawm peb cov transformers, tseem yog lub hauv paus ntawm peb txoj kev mob siab rau kev xa khoom zoo tshaj plaws.
    Yuav kom ntseeg tau tias cov txheej txheem xa khoom du thiab pheej yig, peb tau npaj thiab ntim tag nrho cov transformers kom haum rau hauv ib lub thawv 40HQ, ua kom yooj yim rau kev thauj mus los thiab txo cov nqi thauj mus los.
    Los ntawm kev xaiv JZP transformers, tus neeg siv khoom tuaj yeem ntseeg siab rau lawv qhov kev txiav txim siab los nqis peev rau cov khoom siv hluav taws xob zoo tshaj plaws, cog lus tias yuav ua tau zoo tshaj plaws thiab txuag hluav taws xob. Qhov kev cog lus rau kev ua haujlwm zoo thiab kev ruaj khov no ua raws li peb lub hom phiaj los pab txhawb rau thaj chaw muaj zog ntsuab thiab muaj lub luag haujlwm ntau dua.
    15kVA 21.6kV Ncej Mounted Transformer
    Qhia txog DL-15/21.6/0.24(0.12), lub transformer zoo 15 kVA ib theem uas tau tsim thiab tsim los ntawm JZP Transformer. Lub transformer no ua tau raws li cov qauv nruj ntawm IEEE Std C57.12.00 thiab IEEE Std C57.12.20, ua kom muaj kev ua tau zoo thiab kev nyab xeeb zoo heev.
    Nrog rau qhov ntsuas hluav taws xob siab ntawm 21.6 kV thiab qhov ntsuas hluav taws xob qis ntawm 240V (120V), DL-15/21.6/0.24(0.12) hloov pauv hluav taws xob tau zoo los pab rau ntau yam kev siv. Nws qhov kev tswj hwm hluav taws xob dav dav ntawm 21600V txog 22680V lav qhov tso zis hluav taws xob ruaj khov thiab ruaj khov, ua rau muaj kev ua haujlwm txhim khu kev qha txawm tias nyob hauv cov khoom thauj hloov pauv.
    Yuav kom muab tau kev rwb thaiv tsev thiab kev tiv thaiv zoo, lub transformer muaj BIL (Basic Insulation Level) ntawm 125 kV rau qhov hluav taws xob siab thiab 30 kV rau qhov hluav taws xob qis, tiv thaiv kev nce hluav taws xob thiab ua kom ruaj khov ntev.
    15kVA 21
    15kVA 14.4kV Ncej Mounted Transformer
    Qhia txog JZP-15/14.4(24.94)/0.24(0.12), lub transformer 15 kVA ib theem uas tau teeb tsa los ntawm JZP Transformer uas tau tsim thiab tsim tawm zoo siab.
    Muaj qhov hluav taws xob siab ntawm 14.4 kV thiab qhov hluav taws xob qis ntawm 240V (120V), qhov ntsuas hluav taws xob 15 kVA. Lub DL-15/14.4(24.94)/0.24(0.12) ua kom muaj kev hloov pauv hluav taws xob zoo thiab txhim khu kev qha kom ua tau raws li ntau yam kev xav tau hluav taws xob. Ob qho tib si cov xov hluav taws xob siab thiab qis yog ua los ntawm cov txhuas ruaj khov, ua kom muaj kev ua tau zoo tshaj plaws thiab lub neej ntev.
    Lub transformer yog tsim los nrog additive polarity, kom ntseeg tau tias seamless compatibility thiab txhim kho kev ua haujlwm hauv koj lub zog faib khoom.
    Nrog rau qhov ntsuas hluav taws xob ntawm 13680V txog 15120V, lub transformer no lav qhov tso zis hluav taws xob ruaj khov thiab sib xws, xa cov kev ua tau zoo tshaj plaws hauv qab ntau yam kev mob thauj khoom. Nws qhov BIL (Basic Insulation Level) zoo kawg nkaus ntawm 95 kV thiab 30 kV ua kom muaj kev tiv thaiv zoo tiv thaiv kev nce hluav taws xob, ua kom lub transformer muaj kev ntseeg siab thiab kev nyab xeeb.
    15kVA 14
    15kVA 14.4kV Ncej Mounted Transformer
    Cov kua rwb thaiv tsev uas siv yog cov roj av zoo, tsis muaj PCB, ua rau kev ua haujlwm muaj kev nyab xeeb thiab zoo rau ib puag ncig. Lub tshuab cua txias siv txoj kev ONAN (Oil Natural Air Natural), ua rau cov cua sov ploj mus thiab tswj tau qhov ua haujlwm ntawm lub transformer.
    Tsis tas li ntawd xwb, lub transformer 15kVA 14.4 kV muaj ob lub bushings high-voltage thiab peb lub bushings low-voltage, uas muab kev xaiv sib txuas tau yooj yim. Cov bushings low-voltage tau ua tiav los ntawm cov hlau tooj liab grounding, ua kom muaj kev nyab xeeb ntxiv thaum lub sijhawm ua haujlwm.
    Rau cov ntawv thov peb theem, peb lub transformers 14.4 kV ib theem uas tau teeb tsa rau ntawm ncej tuaj yeem sib koom ua ke kom xa hluav taws xob ntawm 24.94 kV, ua kom tau raws li qhov xav tau ntawm ntau yam kev lag luam thiab kev teeb tsa hluav taws xob.
    Daim Ntawv Qhia Txog Kev Ntsuas Transformer 10kVA Ncej Mounted6
    15kVA 7.2kV Ncej Mounted Transformer
    Qhia txog DL-15/7.2(12.47)/0.24(0.12), yog lub transformer ib theem uas tau tsim thiab tsim los ntawm JZPTransformer. Lub transformer no muaj peev xwm ua tau zoo ntawm 15 kVA, ua rau nws zoo tagnrho rau ntau yam kev siv. Nrog rau qhov ntsuas hluav taws xob thawj zaug ntawm 7.2 kV (12.47 kV) thiab qhov ntsuas hluav taws xob thib ob ntawm 120V (240V), lub transformer no ua kom muaj kev hloov pauv hluav taws xob zoo kom ua tau raws li ntau yam kev xav tau hluav taws xob.
    Txhawm rau kom haum rau ntau yam kev sib txuas thiab daim ntawv thov, DL-15/7.2(12.47)/0.24(0.12) los nruab nrog ob lub bushings high-voltage thiab peb lub bushings low-voltage, uas muaj cov qauv tsim grounding low-voltage rau kev nyab xeeb zoo dua.
    Nrog rau qhov kev tswj hwm qhov hluav taws xob zoo kawg nkaus uas kav ntev txij li 6840V txog 7560V, lub transformer no lav qhov kev tswj hwm qhov hluav taws xob txhim khu kev qha thiab sib xws, ua kom muaj kev faib hluav taws xob ruaj khov thoob plaws ntau yam khoom thauj. Ntxiv mus, DL-15/7.2(12.47)/0.24(0.12) qhia txog kev ua tau ntau yam, vim tias peb lub transformers ib theem ntawm qhov kev tsim no tuaj yeem sib txuas tau yooj yim los ua lub transformer peb theem 12.47 kV, uas ua rau ntau yam kev siv hauv kev lag luam thiab kev siv hluav taws xob.
    Daim Ntawv Qhia Txog Kev Ntsuas Transformer 10kVA Ncej Mounted6
    15kVA 19.2kV Ncej Mounted Transformer
    Lub DL-25/19.92/0.24(0.12), yog lub transformer ib theem 15 kVA zoo kawg nkaus, tsim los ntawm JZP Transformer, thiab ua raws li cov qauv IEEE C57.12.20 thiab ANSI C57.12 nruj heev. Lub transformer no yog tsim los muab kev ua tau zoo tshaj plaws thiab kev ntseeg siab, ua tau raws li ntau yam kev xav tau ntawm cov kab ke faib hluav taws xob niaj hnub. Lub transformer 15kVA muaj depolarization thiab siv Iio vector pawg, ua kom ntseeg tau tias muaj kev ntws hluav taws xob zoo thiab tsis muaj teeb meem, thiab txhim kho kev ua tau zoo thiab kev ruaj khov hauv lub network faib hluav taws xob.
    Daim Ntawv Qhia Txog Kev Ntsuas Transformer 10kVA Ncej Mounted6
    Daim Ntawv Qhia Txog Kev Ntsuas Transformer 10kVA Ncej Mounted
    Ntawm JZP Transformer, qhov zoo yog qhov tseem ceeb tshaj plaws hauv peb txoj kev tsim khoom. Txhua lub transformer uas tau teeb tsa los ntawm tus ncej raug kuaj xyuas tas li ua ntej nws tawm hauv peb lub Hoobkas. Peb ua raws li cov txheej txheem tswj xyuas zoo kom ntseeg tau tias txhua lub transformer ua tau raws li cov qauv kev lag luam siab tshaj plaws thiab ua tau raws li cov neeg siv khoom xav tau.
    Thaum lub sijhawm kuaj xyuas ib txwm, peb cov kws tshaj lij yuav tshuaj xyuas thiab soj ntsuam qhov ua tau zoo ntawm lub transformer, kev nyab xeeb, thiab kev ntseeg tau. Cov yam ntxwv tseem ceeb xws li kev tswj hluav taws xob, kev tiv thaiv rwb thaiv tsev, kev poob ntawm lub zog, kev poob ntawm lub zog tsis muaj zog, thiab impedance raug tshuaj xyuas kom meej kom paub tseeb tias lub transformer ua haujlwm zoo tshaj plaws.
    Tsuas yog tom qab ua tiav qhov kev xeem nruj thiab ua tau raws li txhua yam qauv zoo, lub transformer thiaj li raug suav hais tias tsim nyog rau kev ntim khoom thiab kev xa khoom. Txoj kev ua tib zoo no ua kom peb cov neeg siv khoom tau txais tsuas yog cov transformers zoo tshaj plaws thiab txhim khu kev qha tshaj plaws uas phim lawv cov kev xav tau tshwj xeeb.
    Daim Ntawv Qhia Txog Kev Ntsuas Transformer 10kVA Ncej Mounted6