Ib Theem Ib Lub Transformer Mounted Ncej—37.5 kVA
Kev piav qhia txog khoom
JZP yog ib lub tuam txhab tsim cov transformers uas tau ntawv pov thawj los ntawm CSA, UL, thiab cUL. Lawv tshwj xeeb hauv kev tsim cov transformers zoo 37.5 kVA ib theem ncej mounted uas ua tau raws li cov qauv nruj ntawm ANSI, CSA, IEEE, DOE, thiab IEC. Cov transformers no tau tsim los rau ntau yam kev siv, suav nrog cov khoom siv hluav taws xob, thaj chaw nyob deb nroog, thiab cov kab ke faib hluav taws xob. Nrog kev cog lus ruaj khov rau qhov zoo thiab kev ntseeg siab, JZP cov transformers tau ntseeg siab rau kev ua tau zoo thiab kev ua haujlwm zoo, ua rau lawv yog qhov kev xaiv zoo tshaj plaws rau ntau yam kev xav tau ntawm lub zog.
JZP Transformer muaj lub transformer 37.5 kVA uas siv tau ntau yam thiab ua tau raws li ntau tus qauv thoob ntiaj teb thiab tuaj yeem hloov kho kom haum rau ntau yam kev xav tau. Peb cov transformers tau raug xa tawm mus rau ntau lub tebchaws, suav nrog Tebchaws Meskas, Canada, Panama, Venezuela, thiab Honduras.
Peb muaj peev xwm tsim tau ntau tshaj 500+ lub hauv ib hlis, thiab peb yuav xa khoom sai li ntawm 5-8 lub lis piam. Peb txoj kev cog lus rau qhov zoo tshaj plaws tsis yog tsuas yog tsim khoom xwb, tab sis kuj muaj cov kws tshaj lij hauv Asmeskas uas pab txhim kho thiab kho cov khoom tom qab muag. Qhov no ua kom peb daws tau teeb meem sai thiab daws tau txhua yam teeb meem uas koj ntsib.
Txawm koj yog lub tuam txhab hluav taws xob, tus faib khoom siv hluav taws xob, lossis tus tsim kho, koj tuaj yeem yuav JZP lub transformer ib-theem ncej nrog kev ntseeg siab, paub tias koj tab tom nqis peev rau hauv cov khoom lag luam txhim khu kev qha thiab muaj lub koob npe nrov. Paub txog kev ua haujlwm zoo thiab kev ntseeg siab ntawm JZP Transformer, uas tau tsim los ua kom tau raws li koj cov kev xav tau tshwj xeeb.

37.5 kVA 13.8 kV Transformer
Lub DL-37.5/13.8/0.24(0.12), yog ib-theem ncej-mounted transformer tsim los ntawm JZP Transformer, siv rau IEEE cov qauv thiab DOE 2016 tus qauv kev ua haujlwm zoo. Lub transformer no muaj peev xwm ntawm 37.5kVA, nrog rau qhov nkag siab voltage ntawm 13800V thiab qhov tso zis hluav taws xob qis ntawm 240 (120) V. Nws hom kev sib txuas yog Ii0, muaj qhov tsim qauv polarity subtractive.
Tshwj xeeb tsim rau cov neeg siv khoom Asmeskas, DL-37.5 / 13.8 / 0.24 (0.12) muaj kev ua tau zoo thiab kev ntseeg siab. Nrog JZP txoj kev txawj ntse hauv kev tsim thiab tsim cov transformer, koj tuaj yeem ntseeg siab rau lub transformer kom ua tau raws li koj xav tau zoo.

37.5 kVA 14.4 kV Transformer
Lub DL-37.5/14/0.347, yog lub transformer ib theem uas tau teeb tsa rau ntawm ncej. Lub transformer no ua raws li cov qauv IEEE thiab muaj peev xwm ntawm 37.5 kVA. Nws muaj lub bushing high-voltage, ob lub bushings low-voltage, thiab lub tap changer 5-position, ua kom muaj kev ua haujlwm ntau yam thiab ua haujlwm tau zoo.

37.5 kVA 19.9 kV Transformer
Lub DL-37.5/19.9/0.24(0.12), yog lub transformer uas muaj ncej. Nrog rau qhov ntsuas hluav taws xob siab ntawm 19920V, nws los nrog ob lub bushings hluav taws xob siab thiab peb lub bushings hluav taws xob qis, kom ntseeg tau tias kev faib hluav taws xob tsis muaj teeb meem.
Lub transformer cylindrical zoo nkauj no tau tsim los ua tib zoo kom ua haujlwm tau zoo tshaj plaws thiab ntseeg tau. Nws yog lub transformer ib theem 37.5kVA uas ua raws li tus qauv ANSI C57.12, ua kom muaj kev ua tau zoo thiab kev nyab xeeb.