Leave Your Message

225 kVA 34.5kV 3-Theem Pad Mounted Transformer

Kev Ntsuas Hluav Taws Xob Thawj Zaug: 34.5kV
Kev Ntsuas Hluav Taws Xob Thib Ob: 600/347V
HOM KEV TXUAS: Dyn1
HOM: Pad mounted
Cov Qauv: CSA C227.4
Daim Ntawv Thov: Cov txheej txheem faib khoom lag luam
Kev Ntsuas Fais Fab: 225kVA
Daim Ntawv Pov Thawj: CUL
Txoj Kev Txias: NYOB TWJ YWM THIAB HLUB

    Kev piav qhia txog khoom

    JZP Transformer zoo siab los qhia txog 225 kVA 34.5kV 3-theem pad-mounted transformer, tsim tshwj xeeb rau cov kab ke faib khoom lag luam. Tsim los ntawm cov qauv siab tshaj plaws, nws ua kom muaj zog ruaj khov rau ntau yam kev siv hauv kev lag luam.
    daim ntawv pov thawj01
    daim ntawv pov thawj02
    daim ntawv pov thawj03
    daim ntawv pov thawj04
    daim ntawv pov thawj05
    daim ntawv pov thawj06
    daim ntawv pov thawj07
    daim ntawv pov thawj08
    daim ntawv pov thawj09
    01020304050607
    PEB THEEM PAD MOUNTED TRANSFORMER

    Cov Lus Qhia Txog Kev Siv Transformer 225 kVA 34.5kV

    Lub zog ntsuas 225 kVA
    RATINGPRIMARY VOLTAGE 34500DELTA
    Qhov Hwj Chim Thib Ob 600GrdY/347
    ZAUS 60Hz
    Pawg VECTOR Dyn1
    COV KHOOM SIV CUA Aluminium
    Kev Poob Haujlwm ≤2350W
    TSIS MUAJ KEV Poob Nyiaj ≤650W
    IMPEDANCE VOLTAGE 5.75%
    Qhov siab ≤1,500m
    XIM ANSI 70 Lub teeb grey
    Qhov hnyav ntawm cov roj rwb thaiv tsev 1,040 L
    TAG NRHO QHOB LUJ 2,300 kg
     

    225 kVA 34.5kV Transformer Accessories

    Nqa Lub Rooj ELSP FUSE
    Qhov Rooj Qhib BAYONET FUSE
    Chaw Nres Tsheb KAIS HLOOV
    Lub hau npog lub tank Lub ntsuas roj
    LV BUSHING (4-Qhov) Lub VALVE TXIAV SIAB
    KHOOM SIV LUB SIAB Lub Tshuab Nqus Tsev Siab
    HV GROUNDING COPPER BAR LUB TERMINAL BLOCK
    QHIA TXOG KUB KAW QHOV ROOJ
    Qhov Dej HV Bushing (35kV) Tooj liab hauv av
    Grounding Tooj Liab Bar Kov DAIM NTAWV LUB NPE
    OB LUB CHAW LOADBREAKE HLOOV COV PADS HLAU HAUV AV
    1 "'DRAIN VALVE NROG 3/8" SAMPLER Qhov Rai IR
    1" SAUM TOJ SAUM TOJ SAUM TOJ SAUM TOJ FILTER NIAS KEV TXUAS LUS LUB THAWV CHAW

    Cov Nta Tseem Ceeb
    Qhov Rai IR (Qhov Rai Infrared)
    Txhua lub transformer muaj IR Windows rau ntawm ob qho chaw muaj hluav taws xob siab thiab qis, uas tso cai rau cov neeg teb xov tooj ua cov duab thermal infrared yam tsis tau qhib lub qhov rooj. Qhov kev tsim no ua kom muaj kev tshuaj xyuas zoo thiab muaj txiaj ntsig, ua rau pom tau cov chaw kub lossis cov teeb meem kub dhau. Los ntawm kev txheeb xyuas cov kev pheej hmoo xws li kev thauj khoom ntau dhau, kev sib txuas xoob, lossis kev sib cuag tsis zoo, IR Window txhim kho kev ua haujlwm ntawm transformer kom ruaj khov thiab muaj kev nyab xeeb.

    Cov Khoom Siv Tiv Thaiv Siab Tshaj Plaws
    Lub transformer 225 kVA muaj ntau yam kev tiv thaiv kom ntseeg tau tias muaj kev nyab xeeb thiab lub neej ntev, suav nrog:

    Lub Tshuab Nqus Tsev Siab: Muaj 2 lub tswb ceeb toom rau kev saib xyuas lub siab tiag tiag, muab kev ceeb toom ua ntej txog cov teeb meem uas yuav tshwm sim.

    Lub Cuab Yeej Pab Kom Lub Siab Rov Qab Zoo: Muaj cov khoom sib txuas, nws ua rau muaj lub teeb liab hluav taws xob thaum pom muaj lub siab tsis zoo, ceeb toom rau cov neeg ua haujlwm kom ua cov haujlwm tsim nyog.

    Qhov Qhia Txog Qib Roj: Muaj 2 lub tswb ceeb toom uas ceeb toom rau lub kaw lus saib xyuas thaum qib roj tsis zoo, ua rau cov neeg teb xov tooj tuaj yeem kho qib roj sai sai thiab ua haujlwm kom muaj kev nyab xeeb.

    Qhov Qhia Kub Roj: Muaj 2 lub cim ceeb toom—ib qho rau cov cim ceeb toom thiab ib qho rau cov cim qhia kev mus ncig. Yog tias qhov kub roj tshaj 70°C, lub kaw lus yuav tshaj tawm lus ceeb toom; yog tias nws tshaj 105°C, lub transformer yuav mus ncig tsis siv neeg, thiab lub kaw lus saib xyuas yuav xa ib lub cim los qhia qhov txhaum.

    Tus Neeg Siv Khoom Siv Tau Yooj Yim Tsim & Kev Saib Xyuas Sab Nraud
    Cov Ntsuas Ntsuas Sab Nraud thiab Lub Qhov Dej Nqus & Cov Qauv Ntsuas: Cov neeg ua haujlwm tuaj yeem sim cov roj rwb thaiv tsev thiab tshuaj xyuas cov ntsuas ntsuas yam tsis raug rau cov bushings siab-voltage thiab qis-voltage, txhim kho kev nyab xeeb, kev ua haujlwm zoo, thiab kev ua raws li txoj cai.

    Kev Tiv Thaiv Lub Tshuab Txo Siab: Lub tshuab tiv thaiv no tiv thaiv kev puas tsuaj sab nraud, kev ua haujlwm tsis tau xav txog, thiab kev cuam tshuam los ntawm cov yam ntxwv ib puag ncig, ua kom lub tshuab txo siab ua haujlwm tau zoo thiab txo qhov kev pheej hmoo ntawm cov roj xau. Nws kuj tseem tiv thaiv cov pa phem kom tsis txhob nkag mus rau hauv lub transformer, tswj kev huv thiab kev ruaj khov mus sij hawm ntev.
    Cov Nta Tseem Ceeb

    Kev Ua Haujlwm Zoo & Kev Tsim Kho Tshiab
    Lub transformer 225 kVA los ntawm JZP Transformer tau tsim los nrog kev tsom mus rau kev ntseeg siab thiab kev nyab xeeb mus sij hawm ntev. Nrog cov qhov rai infrared, cov txheej txheem saib xyuas ntse, thiab cov kev tswj hwm sab nraud uas yooj yim siv, lub transformer tsis yog tsuas yog txhim kho kev ua haujlwm zoo xwb tab sis kuj txhim kho kev nyab xeeb ntawm cov haujlwm txij nkawm. Cov yam ntxwv no pab cov neeg ua haujlwm nrhiav thiab daws cov teeb meem uas yuav tshwm sim sai sai, txo qhov tsis ua haujlwm thiab xyuas kom meej tias muaj kev tsim khoom tas mus li.
    Kev Ua Haujlwm Zoo & Kev Tsim Kho Tshiab

    225 kVA Transformer Daim Ntawv Thov
    Cov txheej txheem faib hluav taws xob rau kev lag luam
    Kev muab hluav taws xob rau kev lag luam thiab tsev neeg
    Lub zog rov ua dua tshiab thiab chaw hloov pauv hluav taws xob
    Cov chaw khaws ntaub ntawv thiab cov khoom siv tseem ceeb
    Cov khoom siv fais fab loj
    JZP Transformer—Xyuas kom muaj zog txhim khu kev qha rau koj cov kev xav tau
    JZP Transformer cog lus tias yuav muab cov kev daws teeb meem zoo rau cov neeg siv khoom thoob ntiaj teb. Los ntawm kev siv thev naus laus zis siab heev thiab kev tswj xyuas zoo, peb ua kom muaj kev muab hluav taws xob ruaj khov thiab txhim khu kev qha rau ntau yam haujlwm lag luam thiab kev lag luam. Txawm hais tias nws yog kev teeb tsa khoom siv, kev saib xyuas, lossis kev tsim qauv tshwj xeeb, peb muab cov kev pabcuam tshaj lij thiab kev txhawb nqa.
    225 kVA Transformer Daim Ntawv Thov

    Nug Tam Sim No!

    Yog tias koj muaj lus nug txog peb cov khoom lossis daim ntawv teev nqi, thov tawm koj tus email rau peb thiab peb yuav tiv tauj koj tsis pub dhau 24 teev.

    Leave Your Message