JZP Transformer yog ib lub tuam txhab tsim cov transformers uas muaj cov npe thiab daim ntawv pov thawj UL rau cov qib voltage txog li 44kV, muab ntau yam ntawm UL-certified pad-mounted transformers. Txhua xyoo, peb xa tawm ntau txhiab lub transformers no mus rau Tebchaws Meskas thiab Canada. Peb muaj kev paub txog IEEE/ANSI, CSA, DOE, NEMA, thiab lwm yam qauv, thiab ua kom peb ua raws li ntau yam kev cai lij choj. Ntxiv rau daim ntawv pov thawj UL, peb kuj muaj daim ntawv pov thawj CSA, MF, CESI, thiab cov ntawv xeem SGS sab nraud. Peb muaj kev paub dhau los hauv project, peb nkag siab tias txhua qhov project muaj cov kev cai tshwj xeeb. Yog vim li cas peb thiaj muab cov transformers uas koj tuaj yeem hloov kho tau, uas tso cai rau kev hloov kho voltage, peev xwm, txoj kev sib txuas, thiab kev tsim tshwj xeeb kom haum rau koj cov kev xav tau. Lub transformer 2500 kVA pad mounted tuaj yeem hloov kho kom haum rau koj cov kev xav tau project. Hu rau Daelim Transformer hnub no kom tau txais daim ntawv teev cov ntaub ntawv, cov duab kos, thiab cov lus hais rau lub transformer 2500 kVA pad mounted.
01020304050607
| Cov Lus Qhia Txog Transformer 2500 kVA (2.5 MVA) | |||
| Theem | Peb theem | Tus qauv. | ANSI/IEEE Txuj C57 & DOE 2016 Txuj |
| Kev ntsuas hluav taws xob | 2000kVA (2.5MVA) | Teeb tsa | Tuag pem hauv ntej / voj pub |
| Kev Teeb Tsa | Mount Pad | Zaus | 60Hz |
| HV Voltage | 13200/6720V | Tus kais hloov pauv | 5-txoj haujlwm |
| Lub zog hluav taws xob LV | 600/347V | Peev Xwm Kua | 1600L |
| LUB TSHEB DAB TSI | 95 kV | Qhov hnyav tag nrho | 7000kG |
| LV Tsheb | 30 kV | Tsis muaj kev poob ntawm kev thauj khoom | 2500W |
| Pawg Vector | HauvIn0 | Thaum lub sijhawm poob | 15000W |
| Txoj kev txias | NYOB TWJ YWM THIAB HLUB | Impedance | 5.75% |
| Cov Khoom Siv Winding | Aluminium | Xim pleev xim | Munsell ntsuab |
| Cov kua dej rwb thaiv tsev | Cov roj zaub uas lwj tau | Peev Xwm @ 65 ℃ Kub nce | 2500 kVA |
| Daim ntawv tseem ceeb | Peb theem tsib-kab | Cua Yuam (Kiv cua) | Tsis muaj dab tsi |

2500 kVA Transformer Nta
Lub tshuab hluav taws xob ZGSL-H-2500/13.2-0.6 muaj zog txog 2500 kVA (2.5 MVA). Lub tshuab hluav taws xob 2500 kVA uas tau teeb tsa rau ntawm lub rooj tsavxwm muaj qhov ntsuas hluav taws xob tseem ceeb ntawm 13.2/7.62 kV nrog kev sib txuas Wye, kev siv av hluav taws xob siab H0, thiab qhov hluav taws xob thib ob ntawm 600Y/347V Wye nrog kev siv av hluav taws xob qis H0.
Lub ZGSL-H-2500/13.2-0.6 2500 kVA transformer muaj ntau yam siv, thiab tsim nyog rau kev teeb tsa sab hauv tsev thiab sab nraum zoov. Cov transformers no muaj cov kua roj zaub uas lwj tau thiab tswj tau qhov kub nce 65 ° C. Lawv tuaj nrog 3 ELSP fuses thiab 3 bay-o-net fuses rau kev tiv thaiv, nrog rau 3 lub bushings high-voltage, 3 lub luj tshib (HV), thiab plaub lub bushings low-voltage, txhua lub muaj 6 qhov. Qhov chaw teeb tsa qis-voltage yog txhawb nqa nrog lub phaj Padmount. Tsis tas li ntawd, lub transformer 2500 kVA pad mounted muaj plaub-qhov chaw hloov kho load-break thiab tsib-qhov chaw hloov pauv ntawm sab high-voltage.
ZGSL-H-2500/13.2-0.6
Lub ZGSL-H-2500/13.2-0.6 yog lub transformer peb theem 2500 kVA pad-mounted nrog UL daim ntawv teev npe. Lub transformer 2500 kVA pad mounted ua raws li tus qauv IEEE C57.12.34 thiab ua raws li DOE cov cai. Nws yog tsim los ntawm cov hlau txhuas thiab tau teeb tsa ua lub voj voog-pub hom transformer rau cov kab ke tuag-pem hauv ntej. Txoj kev txias siv yog KNAN.
ZGS-Z-2500(3050)/44/0.6
Lub ZGS-Z-2500(3050)/44/0.6 yog lub transformer tshwj xeeb 2500 kVA live-front pad-mounted uas tsim los ua kom tau raws li cov kev xav tau tshwj xeeb ntawm cov neeg siv khoom Canadian los ntawm Daelim Transformer. Lub transformer 2500 kVA pad-mounted no ua raws li CSA C227.4 thiab CAN/CSA 802.1 cov qauv. Nws muaj qhov hluav taws xob siab ntawm 44 kV hauv Delta configuration thiab qhov hluav taws xob qis ntawm 600GrdY/347V.
Lub transformer muaj roj RAPO uas lwj tau ua nws cov kua rwb thaiv tsev thiab tsim los rau qhov kub nce ntawm 55 ° C lossis 75 ° C. Nws qhov ntsuas kVA yog 2500 kVA (2.5 MVA) ntawm qhov kub nce 55 ° C thiab 3050 kVA ntawm qhov kub nce 75 ° C.
ZGS-Z-2500(3050)/44/0.6
Qhov ua rau lub transformer 2500 kVA no txawv ntawm lwm lub yog nws lub zog hluav taws xob qis tau tsim los tawm ntawm sab. Ntxiv mus, cov ntsuas, lub kais hloov pauv, daim ntawv lo, lub qhov tso pa tawm siab, thiab lub qhov tso pa tawm sab saud tau muab tso rau sab nraud ntawm lub cabin pem hauv ntej. Cov ntsuas no muaj cov khoom sib txuas thiab txuas nrog hauv NEMA 4 lub thawv tswj sab nraum zoov. Lub ntsuas siab nqus tsev nyob rau sab saum toj ntawm lub cabin pem hauv ntej. Lub bushing siab yog lub bushing porcelain integrated nrog plaub lub qhov, thiab sab HV muaj peb lub teeb liab, txhua lub muab lub hau rwb thaiv tsev los tiv thaiv MV cables. Ntxiv mus, cov cua sov tiv thaiv kev sib sau ua ke tau teeb tsa hauv lub cabin siab rau kev ua haujlwm zoo tshaj plaws.

2.5 MVA 3 PH Transformer
Lub ZGSL-Z-2500/44/4.16(2.4) yog lub transformer peb-theem radial pad-mounted tshwj xeeb 2.5 MVA. Nws qhov ntsuas hluav taws xob tseem ceeb yog 44,000 Delta V, thaum lub zog hluav taws xob thib ob yog 4160Y/2400 V. Lub transformer tau teeb tsa nrog pawg txuas hluav taws xob siab thiab qis DYn1, thiab nws ua raws li tus qauv CSA C227.4. Nws muaj kev siv hluav taws xob zoo kawg nkaus ntawm 99.37%, ua raws li tus qauv CAN/CSA-802.3. Lub transformer lub impedance ntawm 85°C yog 5.75%, thiab nws muaj xya theem ntawm kev tswj hluav taws xob rau sab hluav taws xob siab. Nrog lub peev xwm roj rwb thaiv tsev ntawm 2000L thiab qhov hnyav ntawm 7500 kg, nws yog ib qho khoom siv tseem ceeb.

2.5 MVA Transformer
Qhov tseem ceeb, nws muaj tus qauv tsim uas ob qho tib si cov khoom siv hluav taws xob siab thiab qis tau muab tso rau ntawm sab mounting, nrog rau qhov seem hluav taws xob siab muaj lub chamber cua zoo uas txuas mus rau nws lub hauv paus. Kev suav nrog cov twj paj nruag thiab cov khoom siv uas tau teeb tsa zoo rau ntawm phab ntsa roj sab nraud ua rau kev nkag mus tau yooj yim dua thiab ua kom yooj yim dua, piv txwv li lub transformer tus qauv tsim uas tau tsim zoo.

2550 kVA Pad Mounted Transformer
Lub ZGSL-H-2550/34.5/0.415 sawv cev rau lub tshuab hloov pauv peb-theem uas muaj zog, uas muaj zog txog 2550 kVA. Nws zoo heev nrog lub zog siab ntawm 34.5 kV thaum xa cov zis hluav taws xob tsawg ntawm 415Grd/240V. Qhov tseem ceeb, ob qho tib si nws cov hluav taws xob siab (HV) thiab qis hluav taws xob (LV) tau ua los ntawm txhuas. Lub tshuab hloov pauv no muaj qhov ntsuas kev ua haujlwm ntawm 99.4% thiab ua raws li tus qauv IEEE Std C57.12.34. Ntxiv mus, nws suav nrog plaub-txoj haujlwm thauj khoom hloov pauv ua rau muaj kev ua haujlwm thiab kev nyab xeeb.

2550 kVA Transformer
Lub transformer 2550 kVA siv lub tshuab cua txias ONAN/ONAF, yog li ntawd, nws muaj ib pawg kiv cua. Thaum ua haujlwm hauv txoj kev txias ONAN, lub transformer muaj lub zog ntsuas ntawm 2550 kVA. Txawm li cas los xij, txoj kev txias ONAF tuaj yeem tswj tau lub zog ntsuas siab dua ntawm 3300 kVA. Qhov tseem ceeb, lub transformer muaj lub ntsuas kub roj nrog cov neeg tiv tauj ceeb toom thiab txuas nrog lub txee tswj hwm me me 304 stainless hlau. Qhov kev teeb tsa no tso cai rau kev saib xyuas qhov xwm txheej ua haujlwm ntawm lub transformer.
Cov koob ZGSL-H-2550/34.5/0.415 muaj tag nrho plaub chav, tsim tshwj xeeb thiab tsim rau cov neeg siv khoom Asmeskas, thiab yog UL-listed kom ua tau raws li cov qauv kev nyab xeeb thiab zoo.
ZGSL-H-2550/12.47/0.415
Cov koob ZGSL-H-2550/12.47/0.415 muaj ib pawg ntawm 2550 kVA transformers tsim los ntawm JZP Transformer rau cov neeg siv khoom Asmeskas. Cov transformers no yog hom pad-mounted thiab muaj cov qauv pub mov. Cov lus qhia tseem ceeb ntawm cov transformers no suav nrog plaub-txoj haujlwm load-break switch, tsib-txoj haujlwm tap changer, gauges nrog qhov tsis kov feature, peb bay-o-net fuses, thiab ob lub fuses txwv tam sim no.

12.47 kV 2550 kVA Transformer
Ntawm sab qis-voltage, muaj ib lub bracket nyob rau hauv kab los muab kev txhawb nqa rau lub davhlau ya nyob twg. Cov kua rwb thaiv tsev siv yog ASTM II roj av, nrog lub peev xwm ntawm 440 gallons. Lub tank yog tsim los rau qhov siab tshaj plaws ntawm lub tank zoo ntawm 10 PSI thiab lub tank tsis zoo ntawm 8 PSI. Cov kua dej yog khaws cia ntawm 10.0 nti ntawm sab saum toj ntawm lub qhov tes ntawm 25 ℃, nrog rau kev hloov pauv ntawm 0.4 nti ib 10 ℃. Lub tank yog tsim rau 7 PSI nqus tsev filling thiab yog rated rau 2550 kVA thaum energized ntawm 11,847 volts nrog lub kais hloov pauv hauv 124,700-volt txoj haujlwm rau qhov hluav taws xob thib ob ntawm 415Y / 240. Cov transformers no tsis muaj cov qib PCB (tsawg dua 2 ppm) thaum lub sijhawm tsim khoom, ua kom ntseeg tau tias muaj kev nyab xeeb ib puag ncig thiab kev ua raws li txoj cai.

13.2 kV 2550 kVA Transformer
Lub transformer 2550 kVA yog lub transformer tsim tshwj xeeb uas tuav daim ntawv teev npe UL, lav nws ua raws li cov qauv kev nyab xeeb thiab zoo. Pawg txuas rau lub transformer no yog Dy1·Dd0, muab ob txoj kev txuas sib txawv rau qhov hluav taws xob qis:
Rau kev sib txuas 4160V Wye, cov terminals suav nrog X1B, X2B, X3B rau kev sib txuas theem, X1A, X2A, thiab X3A rau kev sib txuas nruab nrab. Rau kev sib txuas 2400V Delta, cov terminals yog raws li nram no: C1B rau X2A, X2B rau X3A, thiab X3B rau X1A.

24.94 kV 2550 kVA Transformer
Tag nrho cov transformers 2550 kVA pad-mounted hauv cov koob no yog tsim los ua kom tau raws li tus qauv IEEE C57.12.34, lav qhov zoo tshaj plaws thiab kev ua tau zoo. Lawv muaj ib qho tsim ntawm sab-mount caj pas rau qhov kev sib txuas qis-voltage, tso cai rau kev sib koom ua ke nrog switchgear. Tsis tas li ntawd, lub qhov hloov pauv load-break rau cov transformers 2550 kVA no yog tsim los ntawm kev txawj ntse hauv lub chamber qis-siab ntawm lub cabin pem hauv ntej, muab plaub qhov chaw rau kev ua haujlwm ntau yam. Lub kais hloov pauv muab tsib qhov chaw, thiab lub iav hloov kho siab tau teeb tsa ntawm 24.94 ± 2 × 2.5% rau kev tswj hwm meej. Lub impedance ntawm cov transformers no ntawm 85 ° C yog 5.87%, ua kom ruaj khov thiab ua haujlwm tau zoo. Ntxiv mus, lawv cov high-voltage thiab low-voltage Basic Insulation Levels (BILs) raug ntsuas ntawm 125kV thiab 30kV, raws li, kom ntseeg tau tias muaj kev ua haujlwm rwb thaiv tsev zoo.
Nug Tam Sim No!
Yog tias koj muaj lus nug txog peb cov khoom lossis daim ntawv teev nqi, thov tawm koj tus email rau peb thiab peb yuav tiv tauj koj tsis pub dhau 24 teev.