138kv 132kv Fais Fab Transformer

Kev Ntsuas Hluav Taws Xob Thawj Zaug: 132kV, 138kV lossis lwm yam
Kev Ntsuas Hluav Taws Xob Thib Ob: 11/10.5/6.6/6.3kV los yog lwm yam
HV KAW QHIA: ± 8 × 1.25% lossis lwm tus
HOM KEV TXUAS: YNd11 lossis lwm tus
HOM: roj immersed transformer

    Kev piav qhia txog khoom

    138 kV thiab 132 kV Transformer yog raws li Tus Qauv 1. GB 6451 Cov Lus Qhia thiab cov kev cai rau cov roj-immersed fais fab transformers; 2. IEC 60076 Fais Fab Transformers; 3. AS NZS 60076 Fais Fab Transformers; 4.CSAC88-16 Fais Fab Transformers; 5. ANSI/IEEE C57.12.00 IEEE Tus Qauv rau Cov Kev Cai Dav Dav rau Liquid-Immersed Distribution, Power, thiab Regulating Transformers; 6. GOST R 52719 Fais Fab Transformers - Cov Lus Qhia Dav Dav; 7. EN60076 Fais Fab Transformer; 8. Cov Kev Pabcuam Tom Qab Muag Khoom Hauv Zos Hauv North America South America thiab lwm thaj chaw teb rau koj cov kev xav tau hauv 24 teev.
    cer
    Daim Ntawv Pov Thawj Transformer 138 kV 132 kV
    Kev tsim thiab tsim cov JZP 138KV 132KV transformers ua tau raws li GB 6451, IEC 60076, AS NZS 60076, CSAC88-16, ANSI/IEEE C57.12.00, GOST R 52719, EN60076 cov qauv. JZP pab pawg kws tshaj lij engineering muaj ntau tshaj 10 xyoo ntawm kev tsim qauv thoob ntiaj teb transformer project. Raws li koj cov kev xav tau thiab cov kev cai lij choj, muab rau koj nrog cov kev daws teeb meem transformer tsim nyog tshaj plaws.
    138 kV thiab 132 kV Transformer yog raws li Standard
    1. GB 6451 Cov Lus Qhia thiab cov kev cai rau cov roj-immersed fais fab transformers;
    2. IEC 60076 Cov Hloov Fais Fab;
    3. AS NZS 60076 Cov Hloov Fais Fab;
    4.CSAC88-16 Cov Hloov Fais Fab;
    5. ANSI/IEEE C57.12.00 IEEE Tus Qauv rau Cov Kev Cai Dav Dav rau Kev Faib Khoom Siv Dej, Fais Fab, thiab Kev Tswj Xyuas Transformers;
    6. GOST R 52719 Cov Hloov Fais Fab - Cov Lus Qhia Dav Dav;
    7. EN60076 Lub Hwj Chim Transformer;
    8. Cov Kev Pabcuam Tom Qab Muag Khoom Hauv Zos Hauv North America South America thiab lwm thaj chaw teb rau koj cov kev xav tau hauv 24 teev.
    Txhua lub transformer 132 kV thiab 138 kV ntawm JZP yuav tsum tau kuaj xyuas raws li cov qauv kev xeem ua ntej tawm hauv lub Hoobkas. Tom qab txhua qhov kev xeem ua tau raws li cov kev cai sib xws, nws raug xa mus rau tus neeg siv khoom kom paub meej tias daim ntawv qhia kev xeem transformer. Nws tuaj yeem ntim thiab xa tuaj.
    Cov Lus Qhia Txog Transformer 138kV thiab 132kV

    132kv Chav Kawm Peb-theem ob winding OLTC fais fab transformer

    Lub zog ntsuas

    Hluav Taws Xob Siab

    Hluav Taws Xob Tsawg

    Tsis muaj kev poob qis (kw)

    Kev poob ntawm kev thauj khoom (kw)

    Tsis muaj qhov tam sim no (%)

    10MVA

    132 kV

    6.3 kV

    11.8

    51.2

    0.82

    12MVA

    138 kV

    6.6 kV

    13.7

    59.5

    0.82

    15MVA

     

    10.5 kV

    16.3

    73.1

    0.76

    20MVA

     

    11 kV

    19.5

    88.4

    0.76

    25MVA

       

    22.7

    105

    0.69

    30MVA

       

    27.4

    126

    0.69

    37.5MVA

       

    32.9

    148

    0.63

    50MVA

       

    38.9

    184

    0.63

    60MVA

       

    46.4

    221

    0.57

    110kv Chav Kawm Peb-theem ob winding NLTC fais fab transformer

    Lub zog ntsuas

    Hluav Taws Xob Siab

    Hluav Taws Xob Tsawg

    Tsis muaj kev poob qis (kw)

    Kev poob ntawm kev thauj khoom (kw)

    Tsis muaj qhov tam sim no (%)

    10MVA

    132 kV

    6.3 kV

    11.8

    51.2

    0.64

    12MVA

    138 kV

    6.6 kV

    12.4

    59.5

    0.64

    15MVA

     

    10.5 kV

    15

    73.1

    0.59

    20MVA

     

    11 kV

    17.8

    88.4

    0.59

    25MVA

       

    21

    105

    0.54

    30MVA

       

    25

    126

    0.54

    37.5MVA

       

    29.9

    148

    0.56

    50MVA

       

    35.3

    178.5

    0.52

    60MVA

       

    41.9

    221

    0.48