    69kV 4200kVA 5250kVA 3 Theem Fais Fab Transformer
    110 kV 115 kV fais fab transformers raws li tus qauv
    1. GB 6451 Cov Lus Qhia thiab cov kev cai rau cov roj-immersed fais fab transformers;
    2. IEC 60076 Cov Hloov Fais Fab;
    3. AS NZS 60076 Cov Hloov Fais Fab;
    4.CSAC88-16 Cov Hloov Fais Fab;
    5. ANSI/IEEE C57.12.00 IEEE Tus Qauv rau Cov Kev Cai Dav Dav rau Kev Faib Khoom Siv Dej, Fais Fab, thiab Kev Tswj Xyuas Transformers;
    6. GOST R 52719 Cov Hloov Fais Fab - Cov Lus Qhia Dav Dav;
    7. EN60076 Lub Hwj Chim Transformer;
    8. Cov Kev Pabcuam Tom Qab Muag Khoom Hauv Zos Hauv North America South America thiab lwm thaj chaw teb rau koj cov kev xav tau hauv 24 teev.
    115kV Transformer
    Lub SF11-20000/115 yog lub tshuab hloov hluav taws xob 115 kV 20 MVA, uas JZP Transformer muab. Lub tshuab hloov hluav taws xob no ua raws li cov qauv tsim khoom nruj ntawm ANSI C57 Std. Nws muaj peev xwm siab voltage ntawm 115 kV thiab qhov ntsuas voltage qis ntawm 13.8 kV.
    JZP Transformer coj ntau yam kev paub dhau los thiab cov ntaub ntawv pov thawj hauv cov haujlwm hloov pauv hluav taws xob siab hauv kev lag luam Asmeskas. Lawv cov pab pawg tshaj lij thiab cov neeg muag khoom qhia txog kev nkag siab tob txog cov cai hauv zos thiab kev ua raws li ANSI, IEEE, thiab CSA cov qauv. Daelim Transformer's HV transformers tau pom cov ntawv thov ua tiav hauv ntau qhov kev teeb tsa thoob plaws Tebchaws Meskas, Canada, Mexico, Australia, Ecuador, thiab lwm lub tebchaws.
    115kV Transformer
    115 kV 20 MVA Transformer Nta
    Voltage: Lub transformer no ua haujlwm ntawm 115 kV thiab muaj peev xwm loj ntawm 20 MVA.
    Lub Tshuab Khaws Roj: Nruab nrog lub tshuab khaws roj rau kev ua haujlwm zoo dua thiab ua haujlwm ntev dua.
    Lub Cim Vector Pawg: Lub transformer ua raws li lub cim Dyn1 vector pawg.
    Cov Txheej Txheem Txias: Siv lub tshuab txias uas yoog tau, suav nrog ONAN, ONAF1, thiab ONAF2 txoj kev. Cov qib fais fab sib txawv raws li cov txheej txheem no: 12 MVA rau ONAN, 16 MVA rau ONAF1, thiab 20 MVA ruaj khov rau ONAF2.
    Cov Qib Rwb Thaiv Kub: Cov qib rwb thaiv kub siab yog teeb tsa ntawm 550 kV, thaum cov qib rwb thaiv kub qis yog 110 kV.
    Kev Ntsuas Kub: Lub tshuab hluav taws xob no yog tsim los tswj qhov kub siab tshaj plaws ntawm 65 ℃ thiab qhov kub siab tshaj plaws ntawm roj yog 55 ℃.
    Tus Hloov Qhov (Tap Changer): Sab HV muaj tus hloov qhov (tap changer) 5-txoj hauj lwm uas siv tau ntau yam, uas tso cai rau tsib theem ntawm kev tswj hwm hluav taws xob hauv qhov ntau ntawm ± 2 × 2.5%.
    Bushings: Cov bushings siab thiab qis-voltage tau yooj yim mounted rau saum.
    Cov Khoom Siv Tiv Thaiv Hluav Taws Xob Loj: Rau kev nyab xeeb thiab kev tiv thaiv zoo dua, sab hluav taws xob siab muaj peb lub khoom siv tiv thaiv hluav taws xob loj.
    115 kV 20 MVA Transformer Nta
    110kV 115kV Transformer
    Cov transformers fais fab 115kV/110kV tau tsim thiab ua kom zoo dua los ntawm kev nqus thiab siv cov thev naus laus zis siab heev hauv tebchaws thiab txawv teb chaws los ua kom zoo dua cov transformer core, coil, lub cev, cov xov hlau, lub tank roj, thiab lwm yam khoom, uas muaj qhov tso tawm tsawg ib feem, poob qis, suab nrov tsawg, lub teeb yuag, thiab kev ntseeg siab siab. Nws qhov kev ua tau zoo heev tau txais kev qhuas siab los ntawm cov neeg siv thiab cov kws tshaj lij. Cov khoom no muaj cov yam ntxwv ntawm kev ruaj khov, kev lag luam, thiab kev tiv thaiv ib puag ncig, thiab tsim nyog rau cov chaw tsim hluav taws xob, cov chaw hloov pauv, cov lag luam loj thiab cov chaw ua haujlwm mineralization, thiab lwm yam.
    110kV 115kV Transformer
    Kev Xeem thiab Kev Tsim Nyog
    Lub transformer 115 kV 20 MVA raug kuaj xyuas ntau yam kom paub tseeb tias nws ua tau raws li cov qauv nruj uas ANSI C57 tau teeb tsa. Cov kev kuaj no suav nrog:
    Kev Ntsuas ntawm Kev Rwb Thaiv Tsev
    Kev Ntsuas ntawm Voltage Ratio thiab Vector Group
    Kev Ntsuas ntawm Cov Kev Ntsuas Winding
    Kev Ntsuas Hluav Taws Xob Sib Cais Qhov Chaw Fais Fab-Zaug
    Kev Ntsuas ntawm Bushing Capacitance thiab Dielectric Dissipation Factor
    Teeb Pom Kev Impulse Voltage Withstand Test
    Kev Ntsuas Hluav Taws Xob Overvoltage Withstand thiab Partial Discharge Test
    Kev Ntsuas ntawm Impedance Voltage thiab Load Losses
    Kev Ntsuas Qhov Ntsuas Impedance ntawm Zero-Sequence
    Kev Ntsuas Qhov Kub thiab Txias
    Kev Ntsuas ntawm Winding Frequency Spectrum Response Curve
    Kev Ntsuas Transformer Tam Sim No Kev Ntsuas Polarity Kev Ntsuas Qhov Ntev
    Cov roj teeb ntawm kev sim no ua kom ntseeg tau tias lub transformer 115 kV ua raws li ANSI C57 tus qauv thiab tau tsim nyog tag nrho, lav nws qhov kev ntseeg tau thiab kev ua tau zoo.
    Kev Xeem thiab Kev Tsim Nyog
    Cov Lus Qhia Txog Lub Hwj Chim Transformer 110kV thiab 115kV
    110kv Peb-theem duplex winding fais fab transformer ntawm load changer
    Kev Ntsuas Voltage Ua Ke Tsis Muaj Kev Poob Haujlwm Kev Poob Haujlwm Tsis muaj Load tam sim no Kev cuam tshuam luv luv
    (kVA) HW LV
    6300 kVA 110kV ±8 6.3kv 10 36 0.8 10.5
    8000 kVA ×1.25% 6.6 kW 12 45 0.8
    10000 kVA   10.5kv 14.2 53 0.74
    12500 kVA 115kV ±8 11kv 16.8 63 0.74
    16000 kVA ×1.25%   20.2 77 0.69
    20000 kVA     24 93 0.69
    25000 kVA     28.4 110 0.64
    31500 kVA     33.8 133 0.64
    40000 kVA     40.4 156 0.58
    50000 kVA     47.8 194 0.58
    63000 kVA     56.8 234 0.52
    110kv Peb theem peb winding fais fab transformer ntawm load changer
    Kev Ntsuas Voltage Ua Ke Tsis Muaj Kev Poob Haujlwm Kev Poob Haujlwm Tsis muaj Load tam sim no
    (kVA) HV (kV) MV (kV) LV (kV)
    6300 kVA 110kv ± 8 35kv 6.3kv 12 47 0.95
    8000 kVA ×1.25% 37kv 6.6 kW 14.4 56 0.95
    10 MVA   38.5kv 10.5kv 17.1 66 0.89
    12.5 MVA 115kv ± 8   11kv 20.2 78 0.89
    16MVA ×1.25%     24.2 95 0.84
    20MVA       28.6 112 0.84
    25MVA       33.8 133 0.78
    31.5MVA       40.2 157 0.78
    40MVA       48.2 189 0.73
    50MVA       56.9 225 0.73
    63MVA       67.7 270 0.67