Kev daws teeb meem Transformer fais fab zoo
Cov Nta Tseem Ceeb & Cov Txiaj Ntsig
Kev Ua Haujlwm Zoo thiab Kev Txuag Hluav Taws Xob
Siv cov khoom siv tseem ceeb (piv txwv li, amorphous alloy) thiab cov qauv tsim winding zoo tshaj plaws, peb cov transformers txo qis kev poob zog (txog li 30% qis dua li cov qauv ib txwm muaj). Qhov no txo cov nqi ua haujlwm thiab txhawb nqa cov kev pib siv hluav taws xob ntsuab.
Kev ntseeg siab ruaj khov
Ua los ntawm cov txheej txheem rwb thaiv tsev zoo thiab cov txheej txheem txias khov kho (ONAN, ONAF, OFAF), cov transformers tiv taus cov xwm txheej ib puag ncig hnyav, kev hloov pauv voltage, thiab kev xav tau ntev. Cov txheej txheem tswj kev kub ua rau lub neej ntev dua.
Cov Qauv Tsim Kho Tau
Muaj nyob rau hauv ib theem lossis peb theem kev teeb tsa, nrog rau qhov ntsuas hluav taws xob txij li 33kV txog 765kV thiab lub peev xwm fais fab txog li 1,000 MVA. Cov kev daws teeb meem tshwj xeeb ua raws li cov ntawv thov tshwj xeeb, xws li kev sib koom ua ke ntawm lub zog rov ua dua tshiab, cov chaw hloov pauv hauv nroog, lossis kev ua haujlwm hauv kev khawb av.
Kev Saib Xyuas Ntse & Kev Nyab Xeeb
Nruab nrog cov sensors uas siv IoT (xaiv tau) rau kev saib xyuas qhov kub thiab txias, voltage, thiab cov xwm txheej thauj khoom tiag tiag. Cov yam ntxwv tiv thaiv siab heev (piv txwv li, Buchholz relays, Buchholz alarms) tiv thaiv kev ua yuam kev thiab xyuas kom muaj kev nyab xeeb.
Kev Ua Raws Cai ntawm Eco-Friendly
Cov suab nrov qis (







Cov ntawv thov
Kev Kis Hluav Taws Xob: Cov transformers nce / nqis rau kev sib txuas ntawm grid thiab cov network substation.
Peb Lub Tuam Txhab Lag Luam: Cov tshuab hnyav, cov chaw tsim khoom, thiab cov lag luam tshuaj lom neeg uas xav tau kev muab hluav taws xob ruaj khov.
Lub Zog Rov Ua Dua Tshiab: Kev koom ua ke nrog cov chaw ua liaj ua teb cua/hnub ci rau kev tshem tawm hluav taws xob zoo.
Kev Lag Luam & Hauv nroog: Cov tshuab HVAC, cov chaw khaws ntaub ntawv, thiab cov khoom siv hauv nroog ntse.
Cov Lus Qhia Txog Kev Siv
Qhov Voltage Ntau: 33kV txog 765kV (qhov hluav taws xob nruab nrab/siab).
Zaus: 50Hz/60Hz.
Hom Txias: Txias los ntawm cua (ONAN), txias los ntawm roj (OFAF).
Chav Kawm Ua Haujlwm Zoo: Ua raws li IEC 61378 (≥99% kev ua haujlwm ntawm tag nrho cov khoom thauj).
Kev Tswj Xyuas Zoo
Txhua chav tsev raug kuaj xyuas nruj heev, suav nrog:
Kev ntsuas kev tiv thaiv rwb thaiv tsev thiab kev ntsuas hluav taws xob impulse.
Kev ntsuas qhov poob ntawm qhov thauj khoom thiab qhov tsis muaj qhov thauj khoom.
Luv-circuit withstand verification.
Tau ntawv pov thawj los ntawm ISO 9001, ISO 14001, thiab KEMA rau kev ua raws li thoob ntiaj teb.
Vim li cas ho xaiv peb?
20+ Xyoo ntawm Kev Paub: Cov ntaub ntawv pov thawj hauv kev tsim cov transformers rau ntau yam lag luam.
Kev Muaj Nyob Thoob Ntiaj Teb: Kev txhawb nqa hauv zos nrog kev pab txhawb nqa 24/7.
Kev Sib Tw Nqe: Cov kev daws teeb meem uas nthuav dav tau raws li cov peev nyiaj thiab kev ua tau zoo.
Kev daws teeb meem tshwj xeeb muaj
Txij li cov modular transformers rau cov chaw nyob deb nroog mus rau cov qauv tsim uas tsis ua rau ib puag ncig puas tsuaj rau cov haujlwm hauv nroog, peb muab kev pabcuam engineering, kev teeb tsa, thiab kev saib xyuas txij thaum pib mus txog thaum kawg.



Cov txiaj ntsig ntawm cov khoom
1. Cov Khoom Siv Tseem Ceeb thiab Kev Tsim Qauv Winding
Cov Khoom Siv Tseem Ceeb
Amorphous Alloy Cores:
Kev poob hlau tsawg heev (qis dua 70–80% piv rau cov hlau silicon ib txwm muaj), txo cov khib nyiab hluav taws xob thiab cov nqi khiav lag luam.
Qhov ze li ntawm xoom magnetostriction txo qhov suab nrov thiab kev co, qhov tseem ceeb rau kev teeb tsa hauv nroog thiab kev lag luam.
Cov Hlau Silicon Uas Muaj Cov Nplej Uas Txias Thiab Dov Tau (CRGO):
Cov laminations txiav los ntawm laser lossis cov kauj ruam lapped txo cov kev poob tam sim no, ua tiav cov theem ua haujlwm tau zoo txog li 99% (IEC 60076 tus qauv).
Qhov ceev ntawm cov hlau nplaum sib nqus siab (piv txwv li, 1.9–2.0 T) txhawb nqa cov ntawv thov hluav taws xob siab (txog li 400 kV).
Kev Tsim Qauv Winding
Cov Ntawv Nyiaj Uas Muaj Roj-Flow Txias:
Cov xov hlau tooj liab lossis txhuas txo cov dej xau thiab cov zog luv luv. Cov kav roj sab hauv ua kom cov cua sov tawm zoo dua.
Cov khaubncaws sab nraud povtseg sib xyaw ua ke txo qhov kev ntxhov siab ntawm qhov hluav taws xob ntawm qhov tig, txhim kho kev tiv thaiv luv luv (txog li 50 kA asymmetrical faults).
Cov Hlau Litz Txheej Txheem:
Cov xov hlau Litz ntau txoj hlua txo cov teebmeem ntawm daim tawv nqaij thiab qhov sib ze, txo cov kev tiv thaiv AC hauv cov xwm txheej siab (piv txwv li, HVDC converters).
Cov xov hlau helical los yog disc:
Zoo rau cov ntawv thov hluav taws xob siab, nrog rau kev rwb thaiv tsev kom tiv taus hluav taws xob impulse voltages (≥1.2 / 50 μs).
2. Cov Txheej Txheem Rwb Thaiv Tsev
Kev rwb thaiv tsev roj-ntawv sib xyaw:
Daim ntawv cellulose impregnated nrog cov roj av lossis cov kua ester muab lub zog dielectric txog li 400 kV BIL.
Tiv taus kev hloov pauv kub (−40 ° C txog + 140 ° C) thiab tswj kev ruaj khov nyob rau hauv cov xwm txheej tso tawm ib nrab.
Kev Ua Epoxy Resin Casting (Hom Qhuav):
Kev siv lub tshuab nqus tsev (VPI) nrog cov epoxy resins Class H ua kom muaj kev tiv thaiv hluav taws (IEC 60335) thiab kev tiv thaiv dej noo.
Nano-Txhim Kho Kev Rwb Thaiv Tsev:
Cov khoom sib xyaw ua ke epoxy uas muaj silica txhim kho qhov tsis kam ntawm kev tso tawm ib nrab los ntawm 40%, ua rau lub neej ntev dua hauv cov chaw noo lossis muaj kuab paug.
3. Kev Tswj Xyuas Kub
Roj-Ntuj Cua Txias (ONAN):
Kev txias tsis siv neeg los ntawm cov radiators thiab cov roj av ntuj rau kev ua haujlwm tas mus li ntawm cov khoom thauj ntsuas (piv txwv li, 100 MVA units).
Kev Siv Cua Txias Yuam (OFAF):
Cov kiv cua tswj tau qhov kub thiab txias ua rau cov cua sov tawm tau zoo dua, ua rau muaj peev xwm ua haujlwm ntau dhau 120–150% rau cov xwm txheej ceev.
Kev Pab Txias Los Ntawm Lub Twj Tso Roj (OFWF):
Cov twj tso kua roj thiab cov kiv cua uas siv cua los ua kom cov cua sov hloov pauv tau zoo rau cov transformers uas muaj peev xwm loj heev (≥500 MVA).
Kev Saib Xyuas Thermal Ntse:
Cov cuab yeej ntsuas fiber-optic thiab IoT systems taug qab cov hotspots, ua rau muaj kev ceeb toom lossis kev hloov kho txias kom tiv thaiv kev puas tsuaj ntawm cov rwb thaiv tsev.
4. Kev Tsim Qauv thiab Kev Tiv Thaiv
Lub tank ruaj khov thiab qhov kaw
Cov Tso Tsheb Hlau Uas Tiv Thaiv Kev Xeb:
Cov hlau kub-dip galvanized lossis txhuas nrog polyurethane / hmoov txheej tiv taus UV degradation, ntsev tsuag, thiab tshuaj lom neeg raug.
Kev Sealing Hermetic:
Cov thoob dej uas vuam los yog ntsia hlau nrog cov gaskets EPDM tiv thaiv kom tsis txhob muaj roj to thiab dej noo nkag, ua kom ntseeg tau tias tsis tas yuav saib xyuas rau 30+ xyoo.
Kev kho mob tiv thaiv corrosion:
Cov txheej txheem tiv thaiv cathodic thiab cov khoom siv stainless-steel txuas ntxiv lub neej nyob rau hauv acidic lossis ntug dej hiav txwv.
Cov yam ntxwv kev nyab xeeb
Cov Li Qub Uas Pab Kom Lub Siab Rov Qab Zoo:
Yuav tso pa tawm thaum muaj teeb meem sab hauv (piv txwv li, luv luv Circuits), tiv thaiv kom lub tank tawg loj heev.
Cov Txheej Txheem ntawm Lub Tank Conservation:
Cov khoom siv kaw kaw txo cov pa oxygen, txo cov oxidation thiab sludge tsim.
Kev tiv thaiv hluav taws xob ntau dhau:
Cov khoom siv zinc oxide arresters (MOA) thiab cov capacitors surge tiv thaiv cov teeb meem xob laim uas ua rau muaj xob laim (≥2.5 kA xob laim).
5. Cov Haujlwm Siab Tshaj Plaws
Cov Txheej Txheem Saib Xyuas Xwm Txheej (CMS):
Cov sensors uas muab tso rau hauv lub cev yuav taug qab qhov kub ntawm roj, kev tshuaj xyuas cov pa roj uas yaj (DGA), cov theem thauj khoom, thiab kev tso tawm ib nrab, ua rau muaj kev saib xyuas ua ntej los ntawm SCADA.
Cov Khoom Siv Hloov Kho Thaum Thauj Khoom (OLTC):
Kev kho qhov kais uas tsav los ntawm AI ua rau kev tswj hwm hluav taws xob zoo dua nyob rau hauv cov khoom siv hluav taws xob hloov pauv, txo cov kev poob hluav taws xob txog li 5%.
Cov Kev Tsim Kho Tshiab Uas Zoo Rau Ib Puag Ncig:
Cov roj rwb thaiv tsev uas ua los ntawm cov khoom siv bio-based (piv txwv li, cov kua ester) uas muaj kev puas tsuaj ntau ntawm cov khoom siv biodegradable (ua raws li OECD 301B) thiab tsis yooj yim kub hnyiab.
Cov Ntawv Thov Tseem Ceeb thiab Cov Qauv Yav Tom Ntej
Kev xa xov hluav taws xob:
Cov chav hluav taws xob siab (220 kV–765 kV) ua rau muaj peev xwm hloov pauv hluav taws xob mus deb nrog qhov poob tsawg kawg nkaus (
Kev Sib Koom Tes Zog Rov Ua Dua Tshiab:
Txhawb nqa HVDC txuas rau cov chaw ua liaj ua teb cua hauv hiav txwv thiab cov chaw tsim hluav taws xob hnub ci.
Kev Nce Qib Yav Tom Ntej:
Cov Transformers Solid-State (SSTs): Ua kom muaj kev hloov pauv DC-DC thiab kev ywj pheej ntawm lub grid rau cov kab ke hluav taws xob tsis muaj chaw.
Kev Kho Tus Kheej Rwb Thaiv: Cov ntaub ntawv Nanocomposite kho tau qhov puas tsuaj me me ntawm dielectric.
Kev piav qhia luv luv
Cov Transformers fais fab zoo tshaj plaws los ntawm cov cores amorphous uas tsis tshua muaj kev poob qis, kev tswj hwm thermal siab heev, thiab ntau txheej kev nyab xeeb. Lawv txoj kev sib xyaw ua ke ntawm kev ua haujlwm zoo, kev nthuav dav, thiab kev ua siab ntev ua rau lawv tsis tseem ceeb rau cov grid niaj hnub, thaum cov kev tsim kho tshiab xws li cov thev naus laus zis solid-state thiab cov roj bio-based tsav kev ruaj khov thiab kev txawj ntse ntawm grid.