Leave Your Message

Cov Roj Transformers 220kVA Ua Haujlwm Zoo Rau Cov Kev Siv Hnyav

Lub ​220kVA Roj Immersed Transformer​ yog ib lub cuab yeej faib hluav taws xob txhim khu kev qha thiab ua haujlwm tau zoo uas tsim los rau kev lag luam, kev lag luam, thiab kev siv hauv paus tsev. Nws siv cov roj av lossis cov roj rwb thaiv tsev uas tsis ua rau ib puag ncig puas tsuaj rau kev txias, ua rau muaj kev hloov pauv hluav taws xob ruaj khov (piv txwv li, 10kV mus rau 0.4kV). Ua los ntawm cov khoom siv ruaj khov thiab cov thev naus laus zis siab heev, nws muaj lub neej ua haujlwm ntev, tsis tas yuav kho, thiab hloov pauv tau rau qhov chaw ib puag ncig hnyav.

    Cov yam ntxwv ntawm cov qauv

    Lub hauv paus
    Cov hlau silicon uas muaj permeability txias-dov nrog cov txheej rwb thaiv tsev kom txo tau cov kev poob tam sim no.
    Tsim peb-theem tsib-limb los txo qhov xoom-sequence impedance thiab tswj cov harmonics.
    Cov cua ntsawj
    Kev Siv Hluav Taws Xob Siab: Cov ntawv ci tooj liab qhwv nrog Nomex daim ntawv interlayer rwb thaiv tsev.
    Kev Tiv Thaiv Hluav Taws Xob Tsawg: Cov qauv cylindrical ntau txheej rau kev tiv thaiv luv luv.
    Lub tank thiab cua txias
    Tsim los ntawm ONAN nrog kev ncig roj ntuj thiab tsis muaj kiv cua sab nraud, zoo tagnrho rau kev teeb tsa sab nraum zoov.
    Cov fins radiator corrugated sib xyaw ua ke rau hauv lub tank rau kev ua kom sov zoo.
    Lub Tshuab Rwb Thaiv Tsev
    Cov roj av (lossis cov roj ester uas zoo rau ib puag ncig) muab kev rwb thaiv tsev, cua txias, thiab kev ploj ntawm arc.
    Qib tso tawm ib nrab ≤50pC (ua raws li IEC 60076).
    Cooper Roj Immersed Transformer Siab Zaus 10001Cooper Roj Immersed Transformer Siab Zaus 10002Cooper Roj Immersed Transformer Siab Zaus 10003
    Lub hauv paus
    • Cov Roj Transformers 220kVA Uas Muaj Kev Ua Haujlwm Zoo Rau Cov Kev Siv Hnyav (1)
    • Cov Roj Transformers 220kVA Uas Muaj Kev Ua Haujlwm Zoo Rau Cov Kev Siv Hnyav (2)
    • Cov Roj Transformers 220kVA Uas Muaj Kev Ua Haujlwm Zoo Rau Cov Kev Siv Hnyav (3)
    • Cov Roj Transformers 220kVA Uas Muaj Kev Ua Haujlwm Zoo Rau Cov Kev Siv Hnyav (4)
    • Cov Roj Transformers 220kVA Uas Muaj Kev Ua Haujlwm Zoo Rau Cov Kev Siv Hnyav (5)
    • Cov Roj Transformers Zoo Tshaj Plaws 220kVA Rau Cov Ntawv Thov Hnyav (6)
    Cooper Roj Immersed Transformer01

    Cov ntawv thov

    Kev faib hluav taws xob rau kev lag luam
    Kev faib hluav taws xob nruab nrab (10kV txog 0.4kV) hauv cov chaw tsim khoom, cov chaw tsuas, thiab cov chaw tsim khoom siv hlau.
    Txhawb nqa lub sijhawm luv luv overload (piv txwv li, hluav taws xob cub tawg, lub cev muaj zog pib).
    Cov Tsev Lag Luam
    Kev faib hluav taws xob rau cov khw loj, cov chaw ua haujlwm, thiab cov tsev so.
    Kev tsim kho vaj tse
    Chaw nres tsheb ciav hlau, tshav dav hlau, thiab cov chaw kho dej khib nyiab.
    Cov Cheeb Tsam Nyob Deb
    Ua haujlwm tau zoo nyob rau hauv cov av noo siab, muaj plua plav, lossis qhov kub thiab txias hloov pauv.

    Cov Txiaj Ntsig Tseem Ceeb

    Kev Ntseeg Siab
    Lub tank kaw tag nrho tiv thaiv cov roj oxidation thiab kev ua qias tuaj.
    Muaj peev xwm tiv taus luv luv (GB/T 1094.5 raws li).
    Kev Saib Xyuas Tsawg
    Tsim qauv uas tsis tas yuav saib xyuas nrog rau kev saib xyuas roj thiab kub hauv lub sijhawm tiag tiag.
    Siv nyiaj tsawg
    Kev nqis peev thawj zaug tsawg thiab kev poob zog ua haujlwm tsawg kawg nkaus.
    Cov Kev Xaiv Zoo Rau Ib Puag Ncig
    Muaj nrog cov roj ester biodegradable (piv txwv li, FR3) rau RoHS ua raws li.

    Cov Lus Qhia Txog Kev Xaiv

    Txhua chav tsev raug kuaj xyuas nruj heev, suav nrog:
    Kev ntsuas kev tiv thaiv rwb thaiv tsev thiab kev ntsuas hluav taws xob impulse.
    Kev ntsuas qhov poob ntawm qhov thauj khoom thiab qhov tsis muaj qhov thauj khoom.
    Luv-circuit withstand verification.
    Tau ntawv pov thawj los ntawm ISO 9001, ISO 14001, thiab KEMA rau kev ua raws li thoob ntiaj teb.

    Cov Lus Qhia Txog Kev Xaiv

    Cov yam ntxwv ntawm kev thauj khoom
    Paub meej tias hom khoom thauj khoom (ruaj khov piv rau hloov pauv).
    Soj ntsuam cov kev xav tau overload luv luv (piv txwv li, cov cub tawg hluav taws xob).
    Cov xwm txheej ib puag ncig
    Qhov siab ≤1,000 meters (yuav tsum tau derating saum toj no).
    Qhov kub thiab txias: -25 ℃ txog +45 ℃ (txias dua rau thaj chaw sov).
    Kev Ua Raws Cai
    Ua tau raws li GB 1094 (Tuam Tshoj), IEC 60076 (thoob ntiaj teb), thiab cov ntawv pov thawj tshwj xeeb hauv kev lag luam (piv txwv li, ATEX rau cov huab cua tawg).

    Kev Teeb tsa thiab Kev Txij Nkawm

    Cov Kev Cai Rau Kev Teeb Tsa
    Lub hauv paus tiaj tus nrog ≥1m qhov chaw seem ntawm txhua sab rau kev tso cua sov tawm.
    Kev tiv thaiv av ≤4Ω; tsim kev tiv thaiv xob laim cais.
    Kev Txij Nkawm Tsis Tu Ncua
    Xyuas seb roj npaum li cas, xim, thiab qhov xau txhua 6 lub hlis.
    Sim ntsuas qhov tsis kam ntawm rwb thaiv tsev txhua xyoo siv lub ntsuas hluav taws xob 2,500V megohmmeter.
    Kev daws teeb meem
    Kub Dhau: Tshawb xyuas qhov txhaws ntawm lub radiator lossis cov khoom thauj tsis zoo.
    Kev Tshuaj Xyuas Roj Chromatography: Tshawb nrhiav cov cim qhia ntxov ntawm kev tso tawm sab hauv lossis kev puas tsuaj ntawm cov khoom rwb thaiv tsev.
    Cooper Roj Immersed Transformer02Cooper Roj Immersed Transformer03Cooper Roj Immersed Transformer04Cooper Roj Immersed Transformer05

    Vim li cas ho xaiv peb

    JIEZOU POWER, tus kws tsim qauv tshaj lij, chaw tsim khoom thiab tus neeg teeb tsa kev daws teeb meem fais fab thoob ntiaj teb, tau tsim muaj xyoo 1989, nyob hauv 200,000 square meter.
    JIEZOU POWER, feem ntau tswj hwm cov haujlwm fais fab, 500KV EPC, 230KV hydroelectric fais fab nroj tsuag, 115KV fais fab substation, thiab lwm yam.
    Lub Hoobkas JIEZOU POWER tuaj yeem tsim cov roj hom thiab hom qhuav faib hluav taws xob, max 500KV 480MVA fais fab transformer, GIS, switchgear, substation, raws li ANSI / IEEE / DOE2016 / CSA / IEC60076 tus qauv.
    JIEZOU POWER tau txais daim ntawv pov thawj ISO9001, ISO14001, ISO45001, UL, CUL, CSA, SGS, TUV, INTERTEK, TYPE TEST REPORT. Txog xyoo 2023, cov tuam txhab ceg thoob ntiaj teb thiab cov chaw tsim khoom tau muab faib rau hauv Tebchaws Meskas, Canada, Dubai, Dominican Republic, Philippines, cov chaw tsim khoom ceg Suav thiab cov tuam txhab nyob hauv nroog BengBu, nroog FengYang, nroog HaiAn, nroog TaiZhou, nroog SuZhou, nroog ShenYang, nroog FoShan.
    Saib mus rau yav tom ntej, JIEZOU POWER lub zeem muag yog ua tus muab kev daws teeb meem fais fab uas ntseeg siab tshaj plaws, daws cov teeb meem kev tswj hwm fais fab sai tshaj plaws hauv ntiaj teb, ua kom lub ntiaj teb hloov mus rau lub zog rov ua dua tshiab sai dua. Yog li txhua tus neeg tuaj yeem muaj lub neej uas tsis muaj carbon ntau thiab ci ntsa iab. Txog qhov kawg no, peb yuav ua peb qhov zoo tshaj plaws los siv zog.
    Cooper Roj Immersed Transformer06Cooper Roj Immersed Transformer07Cooper Roj Immersed Transformer08Cooper Roj Immersed Transformer09

    Nug Tam Sim No!

    Yog tias koj muaj lus nug txog peb cov khoom lossis daim ntawv teev nqi, thov tawm koj tus email rau peb thiab peb yuav tiv tauj koj tsis pub dhau 24 teev.

    Leave Your Message