+86 18068001229 01
Cov Transformers Sab Nraud Ib Leeg Uas Muaj Pad-Mounted Zoo
Cov Nta Tseem Ceeb
Kev Tsim Qauv Me Me & Ruaj Ntseg: Nyob rau hauv cov thawv uas tiv taus huab cua, thiab xauv tau (feem ntau yog hlau lossis txhuas uas tiv taus xeb), cov chav no tiv thaiv cov khoom sab hauv los ntawm kev ua phem, huab cua, thiab kev sib chwv tsis tau xav txog.
Kev Ua Haujlwm Zoo: Siv cov ntaub ntawv tseem ceeb zoo tshaj plaws (piv txwv li, hlau amorphous lossis hlau silicon uas yog cov noob) thiab cov xov hlau uas tau tsim los kom txo qhov kev poob zog, ua tau raws li DOE 2016 thiab IEC 60076 cov qauv kev ua haujlwm zoo.
Kev Ua Haujlwm Suab Nrov Tsawg: Tsim los ntawm cov ntaub ntawv uas txo suab nrov thiab cov voj voog sib nqus zoo tshaj plaws, zoo tagnrho rau cov chaw uas rhiab suab nrov xws li cov zej zog thiab tsev kho mob.
Kev Txij Nkawm Tsawg: Kev tsim kho kaw (roj puv los yog qhuav) tiv thaiv kev ua qias tuaj, thaum cov txheej txheem saib xyuas siab heev ua rau muaj kev txij nkawm ua ntej.
Kev Ua Raws Cai Kev Nyab Xeeb: Muaj cov qhov rooj uas tau av, cov cim qhia txog qhov txhaum, cov khoom siv txo qhov siab, thiab cov qauv tsim uas tiv taus arc. Cov qauv uas muaj roj siv cov kua uas tiv taus hluav taws lossis cov kua uas lwj tau.




Cov Lus Qhia Txog Kev Siv
Kev Ntsuas Hluav Taws Xob: Lub zog hluav taws xob tseem ceeb yog txij li 2.4 kV txog 34.5 kV, nrog rau cov zis thib ob ntawm 120/240V lossis 230/400V (ib theem).
Peev Xwm: Muaj txij li 25 kVA txog 500 kVA, txhawb nqa ntau yam kev xav tau thauj khoom, suav nrog cov tsev nyob sib koom ua ke thiab cov chaw ua lag luam me.
Txias: Cov qauv siv roj-immersed (ONAN) lossis hom qhuav (ventilated lossis encapsulated), nrog rau qhov kub nce siab raws li IEEE C57.12.25.
Kev Ntsuas Kev Tiv Thaiv: Cov ntaub thaiv uas ntsuas IP55 lossis siab dua rau kev tiv taus plua plav thiab dej.
Cov ntawv thov
Kev Faib Tawm Hauv nroog: Zoo tagnrho rau cov tes hauj lwm fais fab hauv av hauv nroog, cov cheeb tsam nyob ib puag ncig, thiab cov zej zog uas tau npaj tseg.
Thaj Chaw Lag Luam: Muaj zog rau cov chaw yuav khoom, cov chaw ua haujlwm, thiab cov kev tsim kho sib xyaw nrog qhov cuam tshuam tsawg kawg nkaus.
Cov Txheej Txheem Fais Fab Rov Ua Dua Tshiab: Sib koom ua ke nrog lub hnub ci/cua teeb tsa lossis microgrids rau kev faib hluav taws xob hauv zos.
Cov Kev Tsim Kho Tseem Ceeb: Txhawb nqa cov tsev kho mob, tsev kawm ntawv, thiab cov chaw khaws ntaub ntawv uas xav tau lub zog txhim khu kev qha thiab suab nrov tsawg.
Cov Zoo Dua Lwm Txoj Hauv Kev
Kev Ua Haujlwm Zoo ntawm Qhov Chaw: Tshem tawm qhov xav tau cov ncej, tso qhov chaw saum huab cua thiab txo qhov pom kev tsis meej.
Kev Nyab Xeeb Zoo Dua: Cov chaw kaw hauv av tiv thaiv pej xeem nkag mus, txo cov kev pheej hmoo raug hluav taws xob.
Kev nthuav dav: Cov qauv tsim modular tso cai rau kev txhim kho peev xwm yooj yim kom phim cov kev xav tau zog uas loj hlob tuaj.
Kev ruaj khov: Cov ntaub ntawv tiv taus corrosion thiab kev tsim kho ruaj khov ua kom muaj lub neej ntev hauv cov chaw ib puag ncig hnyav.
Kev Teeb tsa & Kev Txij Nkawm
Kuvkev teeb tsa: Tau teeb tsa rau ntawm cov pob zeb ua vaj tse uas muaj cua nkag thiab dej ntws zoo. Yuav tsum tau npaj qhov chaw tsawg kawg nkaus piv rau cov qhov av hauv av.
Kev Nkag Tau: Kev tsim qauv nkag mus rau pem hauv ntej ua rau kev saib xyuas, kev tshuaj xyuas, thiab kev kho yooj yim yam tsis tas yuav rhuav tshem lub tshuab.
Kev Saib Xyuas: Cov qauv siab heev suav nrog IoT-enabled sensors rau kev taug qab lub sijhawm tiag tiag ntawm cov khoom thauj, qhov zoo ntawm roj (yog tias siv tau), thiab qhov kub.
Lub Neej Nyob: Tsim los rau 30–40 xyoo ntawm kev pabcuam nrog kev tshuaj xyuas tsis tu ncua (piv txwv li, kev kuaj roj, kev kuaj xyuas bushing, thiab kev thaij duab thermal).
Kev Ua Raws Cai & Kev Ruaj Ntseg
Ua raws li IEEE C57.12.25, IEC 60076, thiab NEMA ST-20 cov qauv.
Cov kev xaiv uas zoo rau ib puag ncig suav nrog cov transformers qhuav (tsis muaj roj), cov ntaub ntawv pov tseg uas siv tau dua tshiab, thiab cov kua dej rwb thaiv tsev uas lwj tau.
Lub transformer uas tau teeb tsa rau ntawm ib theem yog ib qho kev daws teeb meem uas siv tau ntau yam, muaj kev nyab xeeb, thiab ua haujlwm tau zoo rau cov tes hauj lwm faib hluav taws xob niaj hnub no. Nws qhov kev teeb tsa hauv av, ua ke nrog kev ruaj ntseg zoo thiab kev cuam tshuam tsawg rau ib puag ncig, ua rau nws tseem ceeb rau cov chaw muab kev pabcuam thiab cov neeg tsim khoom uas muab kev nyab xeeb, kev zoo nkauj, thiab kev ntseeg siab rau kev ua haujlwm. Txawm hais tias muab hluav taws xob rau cov zej zog hauv nroog lossis cov chaw siv hluav taws xob rov ua dua tshiab, lub transformer no sib npaug kev ua tau zoo nrog kev ruaj khov.



Cov txiaj ntsig ntawm cov khoom
1. Cov Khoom Siv Tseem Ceeb thiab Kev Tsim Qauv Winding
Cov Khoom Siv Tseem Ceeb
Cov Cores Amorphous Alloy: Siv cov hlau amorphous uas tsis tshua muaj kev poob, muab 70–80% qis dua kev poob hlau piv rau cov hlau silicon ib txwm muaj. Lawv qhov kev nkag tau zoo thiab ze li ntawm xoom magnetostriction txo cov suab nrov thiab kev co, zoo tagnrho rau thaj chaw nyob.
Hlau Silicon Qib: Cov hlau silicon dov txias uas muaj cov laminations txiav laser txo qhov sib txawv ntawm huab cua thiab kev poob tam sim no, txhim kho kev ua haujlwm zoo (txog li 98%) thiab kev ruaj khov thermal.
Kev Tsim Qauv Winding
Kev Tsim Qauv Winding
Cov Ntawv Nyiaj Hluav Taws Xob: Cov ntawv nyiaj hluav taws xob tooj liab lossis txhuas txo cov dej xau thiab cov zog luv luv, ua kom muaj kev tiv taus kev thauj khoom ntau dhau.
Hlau Litz Txheej: Cov xov hlau Litz ntau txoj hlua txo cov teebmeem ntawm daim tawv nqaij thiab qhov sib ze, ua kom zoo dua qhov kev faib tawm tam sim no thiab kev ua haujlwm zoo.
Kev Npaj Coil Me Me: Kev nias axial thiab cov txheej txheem impregnation resin txhim kho lub zog kho tshuab thiab kev ua kom sov tau zoo.
2. Cov Txheej Txheem Rwb Thaiv Tsev
Kev Ua Epoxy Resin Casting: Cov transformers qhuav siv cov impregnation nqus tsev (VPI) nrog cov epoxy resin kub siab (Class H rwb thaiv tsev), muab UL-certified hluav taws thiab noo noo tiv taus.
Kev Rwb Thaiv Hluav Taws Xob Uas Muaj Roj: Rau cov chav tsev muaj peev xwm siab, cov roj rwb thaiv hluav taws xob zoo (piv txwv li, cov kua ester-based) ua ke nrog daim ntawv Nomex muab kev nyab xeeb hluav taws thiab lub zog dielectric txog li 200 kV.
Kev Rwb Thaiv Nano-Txhim Kho: Cov khoom sib xyaw ua ke epoxy uas muaj silica txhim kho kev tiv thaiv ib nrab ntawm kev tso tawm, ua kom lub neej ua haujlwm ntev dua hauv qhov chaw noo lossis muaj kuab paug.
3. Kev Tswj Xyuas Kub
Cua Txias Los Ntawm Roj: Cov roj ncig thiab cov finned radiators muab kev txias tsis siv neeg rau kev ua haujlwm siab tas mus li.
Kev Siv Cua Txias: Cov kiv cua tswj qhov kub thiab txias yuav ua haujlwm thaum qhov kub ntawm roj tshaj qhov txwv, ua kom muaj kev nyab xeeb.
Cov Sensors Thermal Ntse: Cov thermistors uas muab tso rau hauv thiab cov tshuab saib xyuas IoT ua rau muaj kev ceeb toom lossis cov txheej txheem tshem tawm cov khoom siv kom tiv thaiv kev kub dhau.
4. Kev Tsim Qauv thiab Kev Tiv Thaiv
Tsim Qauv Modular thiab Compact
Lub thawv ntim khoom uas muaj hauv paus: Cov pob zeb ua los ntawm cov pob zeb khov kho lossis cov polymer uas ruaj khov ua kom ruaj khov thiab tiv taus kev tub sab.
Kev Sib Nqus IP68-Rated: Cov thawv Hermetic nrog cov gaskets EPDM tiv thaiv dej, hmoov av, thiab nas nkag, txawm tias nyob rau hauv thaj chaw uas muaj dej nyab ntau.
Cov Txheej Txheem Tiv Thaiv Kev Xeb: Cov hlau galvanized kub lossis cov hlau txhuas nrog cov txheej polyurethane hmoov tiv taus kev puas tsuaj UV thiab tshuaj tsuag ntsev.
Cov yam ntxwv kev nyab xeeb
Kev Tiv Thaiv Surge Sab Hauv: Cov Zinc oxide surge arresters (MOA) thiab surge capacitors tswj cov transients uas raug xob laim.
Cov Li Qub Txo Siab: Tso pa tawm thaum muaj teeb meem sab hauv, tiv thaiv kev tawg.
Tsim Kom Tsis Txhob Muaj Kev Ua Phem: Cov vaj huam sib luag nkag tau uas xauv tau thiab cov cim tiv thaiv kev tub sab uas siv GPS tiv thaiv kev ua phem yuav tiv thaiv tau kev ua phem.
5. Cov Haujlwm Siab Tshaj Plaws
Cov Txheej Txheem Saib Xyuas Xwm Txheej: Cov sensors uas ua rau hauv lub tshuab ntsuas qhov kub ntawm roj, qib roj thauj khoom, thiab qhov tso tawm ib nrab, xa cov ntaub ntawv mus rau SCADA systems rau kev saib xyuas ua ntej.
Kev Txhim Kho Lub Zog Kom Zoo: Cov algorithms uas tsav los ntawm AI hloov kho cov kais hloov pauv kom txo qis kev poob hauv qab ntau yam kev mob thauj khoom.
Cov Qauv Tsim Uas Zoo Rau Ib Puag Ncig: Cov roj rwb thaiv tsev uas ua los ntawm cov khoom siv bio-based thiab cov khoom siv polymer uas siv tau dua tshiab ua raws li cov hom phiaj kev ruaj khov.
Cov Ntawv Thov Tseem Ceeb thiab Cov Qauv Yav Tom Ntej
Zoo tagnrho rau cov chaw hloov hluav taws xob hauv nroog, kev sib koom ua ke ntawm lub zog rov ua dua tshiab (piv txwv li, cov liaj teb hnub ci), thiab cov chaw ua lag luam.
Cov kev nce qib yav tom ntej suav nrog cov khoom siv hloov pauv solid-state (SSTs) rau kev ywj pheej ntawm lub grid thiab cov ntaub ntawv rwb thaiv tsev uas kho tau tus kheej kom txo lub sijhawm tsis ua haujlwm.
Kev piav qhia luv luv
Cov Transformers Ib Leeg-Theem Pad-Mounted zoo tshaj plaws los ntawm cov cores amorphous uas tsis tshua muaj kev poob qis, kev tswj hwm thermal ntse, cov qauv tsim modular, thiab cov txheej txheem tiv thaiv ntau txheej. Lawv qhov kev sib xyaw ua ke ntawm kev ua haujlwm zoo, kev nyab xeeb, thiab kev hloov pauv tau ua rau lawv yog lub hauv paus ntawm cov tes hauj lwm faib khoom niaj hnub, nrog rau kev tsim kho tshiab tas mus li tsav tsheb ntsuab dua, ntse dua.



Nug Tam Sim No!
Yog tias koj muaj lus nug txog peb cov khoom lossis daim ntawv teev nqi, thov tawm koj tus email rau peb thiab peb yuav tiv tauj koj tsis pub dhau 24 teev.








