Leave Your Message

Xov xwm

Kev Siv Roj-Immersed Transformer Winding: Kev Nkag Siab Txog Kev Siv Tshuab thiab Cov Qauv Tsim

Kev Siv Roj-Immersed Transformer Winding: Kev Nkag Siab Txog Kev Siv Tshuab thiab Cov Qauv Tsim

2025-08-20

Cov roj transformer windings yog cov khoom tseem ceeb hauv cov kab ke faib hluav taws xob, tsim los kom xa hluav taws xob tau zoo thaum ua kom ntseeg tau tias muaj kev ntseeg siab thiab ruaj khov.

saib cov ntsiab lus
Cov roj transformers uas tau muab tso rau hauv dej tsis tas yuav hloov roj ntau zaus, tab sis kev saib xyuas tsis tu ncua yog qhov tseem ceeb

Cov roj transformers uas tau muab tso rau hauv dej tsis tas yuav hloov roj ntau zaus, tab sis kev saib xyuas tsis tu ncua yog qhov tseem ceeb

2025-08-16

Yuav kom ntsuam xyuas seb puas yuav tsum tau hloov roj rau lub tshuab hloov pauv roj, cov kev kuaj xyuas txij nkawm hauv qab no yuav tsum tau ua ...

saib cov ntsiab lus
Lub transformer puas tso tawm hluav taws xob?

Lub transformer puas tso tawm hluav taws xob?

2025-08-14

Nyob rau hauv cov ntsiab lus ntawm electromagnetic ib puag ncig thiab kev noj qab haus huv pej xeem, transformers thiab lwm yam kev xa hluav taws xob thiab kev hloov pauv tsim cov teb hluav taws xob thiab cov teb sib nqus - hu ua "electromagnetic fields" (EMF) - tsis yog "electromagnetic radiation."

saib cov ntsiab lus
Kev qhia luv luv ntawm lub tshuab hluav taws xob transformer

Kev qhia luv luv ntawm lub tshuab hluav taws xob transformer

2025-08-14

Lub tshuab txuag roj yog ib lub cuab yeej khaws roj siv hauv lub transformer. Nws lub luag haujlwm yog los nthuav cov roj hauv lub tank roj thaum qhov kub ntawm cov roj nce vim yog qhov nce ntawm qhov hnyav ntawm lub transformer.

saib cov ntsiab lus
Transformer Tap Changer

Transformer Tap Changer

2025-08-06

Lub cuab yeej tswj hluav taws xob ntawm lub transformer yog muab faib ua lub transformer "off-excitation" voltage regulating device thiab lub transformer "on-load" tap changer.

saib cov ntsiab lus
Lub Luag Haujlwm ntawm IFD hauv Transformers: Tus Saib Xyuas Lub Hwj Chim Grid

Lub Luag Haujlwm ntawm IFD hauv Transformers: Tus Saib Xyuas Lub Hwj Chim Grid

2025-08-01

Koj puas paub tias cov transformers niaj hnub nim no ntse zuj zus thiab tuaj yeem nrhiav tau teeb meem ntawm lawv tus kheej? Ntsib qhov IFD sensor (Sab hauv Fault Detector)—ib lub cuab yeej me me tab sis muaj zog uas ua lub luag haujlwm tseem ceeb hauv kev ua kom cov transformers muaj kev nyab xeeb thiab ua haujlwm tau zoo.

saib cov ntsiab lus
Cov Transformers Earthing

Cov Transformers Earthing

2025-08-01

Ib lub transformer earthing, tseem hu ua grounding transformer, yog ib hom transformer uas siv los tsim kev sib txuas hauv av tiv thaiv rau cov kab ke hluav taws xob.

saib cov ntsiab lus
Tshawb Nrhiav Lub Luag Haujlwm ntawm Cov Transformers Cia Khoom Siv Hluav Taws Xob

Tshawb Nrhiav Lub Luag Haujlwm ntawm Cov Transformers Cia Khoom Siv Hluav Taws Xob

2025-07-25

Raws li lub ntiaj teb lub zog hluav taws xob hloov pauv sai sai mus rau cov peev txheej rov ua dua tshiab, qhov tseem ceeb ntawm cov txheej txheem khaws cia hluav taws xob zoo yeej tsis tau muaj dua li no.

saib cov ntsiab lus
Txhim Kho Koj Lub Hwj Chim Infrastructure nrog JZP ntawm 2025 3E XPO

Txhim Kho Koj Lub Hwj Chim Infrastructure nrog JZP ntawm 2025 3E XPO

2025-07-24

Raws li lub ntiaj teb lub zog hluav taws xob hloov zuj zus, qhov kev thov rau cov kev daws teeb meem hluav taws xob uas muaj zog, ua haujlwm tau zoo, thiab ruaj khov yeej tsis tau tseem ceeb npaum li no.

saib cov ntsiab lus
Cov Khoom - Cov Ntaub Ntawv Ua Tiav

Cov Khoom - Cov Ntaub Ntawv Ua Tiav

2025-07-19

Xyoo 2025, peb tau xa ib lub transformer 12 MVA mus rau Philippines. Lub transformer no muaj lub zog ntsuas ntawm 12,000 KVA thiab ua haujlwm ua lub transformer step-down, hloov lub zog hluav taws xob tseem ceeb ntawm 66 KV mus rau lub zog hluav taws xob thib ob ntawm 33 KV.

saib cov ntsiab lus