+86 18068001229 Lub transformer immersed roj zaub yog dab tsi?
Cov roj zaub uas tau muab tso rau hauv lub tshuab hluav taws xob yog ib hom tshuab hluav taws xob uas siv cov roj zaub ua lub rwb thaiv tsev thiab cua txias, thiab cov roj zaub feem ntau siv cov roj zaub uas muaj hluav taws xob ntau, xws li cov roj taum pauv, cov roj canola, thiab lwm yam. Kev siv cov roj zaub tuaj yeem ua rau lub cev puas tsuaj, txo cov pa phem ib puag ncig, nrog rau kev ua haujlwm rwb thaiv tsev zoo, tuaj yeem cais cov winding thiab hlau core, kev nyab xeeb dua thiab tsis kub hnyiab.
Zaub Roj Transformer puas yog ib hom transformer?
Roj transformer yog ib hom fais fab transformer uas siv cov roj zaub ntuj ua rwb thaiv tsev thiab cua txias. Piv nrog cov transformers ib txwm siv cov roj av, cov roj zaub transformers muaj cov yam ntxwv thiab qhov zoo hauv qab no:
- Kev tiv thaiv ib puag ncig
Biodegradable: Cov roj zaub yog los ntawm cov nroj tsuag ntuj thiab biodegradable thiab zoo rau ib puag ncig.
Tsis muaj tshuaj lom thiab tsis ua rau muaj kev phom sij: Cov roj zaub tsis muaj tshuaj lom, thiab txawm tias nws xau, nws yuav tsis ua rau av thiab dej qias neeg.
Cov peev txheej rov ua dua tshiab: Roj zaub yog cov peev txheej rov ua dua tshiab, raws li lub tswv yim ntawm kev txhim kho kom ruaj khov.
2. Kev Ruaj Ntseg
Qhov kub hnyiab siab: Cov roj zaub muaj qhov kub hnyiab siab dua li cov roj av, uas muaj kev tiv thaiv hluav taws zoo dua thiab txo qhov kev pheej hmoo ntawm hluav taws.
Kev hloov pauv qis: Cov roj zaub tsis tshua muaj kev hloov pauv, txo cov pa phem uas tsim tawm thaum lub sijhawm ua haujlwm.
- Qhov zoo ntawm kev ua tau zoo
Kev ua tau zoo heev ntawm kev rwb thaiv tsev: Kev ua tau zoo ntawm kev rwb thaiv tsev ntawm cov roj zaub yog qhov zoo, uas tuaj yeem tiv thaiv cov khoom siv hluav taws xob hauv lub transformer.
Kev ua haujlwm txias zoo: Cov roj zaub muaj kev ua haujlwm hloov pauv cua sov siab, uas tuaj yeem ua rau cov transformers txias thiab ntev lawv lub neej kev pabcuam.
Ua kom lub neej ntawm cov khoom siv ntev dua: Vim yog qhov ruaj khov tshuaj zoo ntawm cov roj zaub, nws tuaj yeem txo qhov oxidation thiab kev laus hauv lub transformer, yog li ua kom lub neej ntawm lub transformer ntev dua.
- Daim ntawv thov teb
Lub zog fais fab hauv nroog: tsim nyog rau thaj chaw nyob, thaj chaw ua lag luam, tsev kho mob, tsev kawm ntawv thiab lwm qhov chaw uas muaj kev xav tau siab rau kev tiv thaiv ib puag ncig thiab kev nyab xeeb.
Kev lag luam thiab kev lag luam mining: tsim nyog rau roj av, tshuaj lom neeg, metallurgy thiab lwm yam lag luam nrog cov kev cai nruj heev ntawm kev nyab xeeb hluav taws.
Lub zog tshiab: tsim nyog rau cov liaj teb cua, cov chaw tsim hluav taws xob photovoltaic thiab lwm yam haujlwm tsim hluav taws xob rov ua dua tshiab.
- Cov qauv yav tom ntej
Nrog kev txhim kho ntawm kev paub txog ib puag ncig thiab kev nce qib ntawm thev naus laus zis, cov roj transformers zaub maj mam hloov cov roj transformers ib txwm muaj thiab dhau los ua qhov kev xaiv tshiab rau kev lag luam fais fab.
Dab tsi yog cov yam ntxwv ntawm cov roj zaub immersed transformer?
- Kev Ua Haujlwm Zoo
Kev Poob Qis Tsis Muaj Khoom Thauj Khoom Thiab Kev Poob Khoom Thauj Khoom: Cov transformers no yog tsim los txo qhov kev poob ntawm lub hauv paus (tsis muaj khoom thauj khoom) thiab tooj liab (khoom thauj khoom), kom ntseeg tau tias muaj kev ua haujlwm zoo thaum lub sijhawm ua haujlwm.
Kev Ua Raws Li Cov Qauv Zog: Lawv feem ntau ua tau raws li lossis tshaj cov qauv kev siv hluav taws xob thoob ntiaj teb xws li IEEE, IEC, lossis cov cai hauv zos.
- Kev rwb thaiv tsev roj zaub
Eco-Friendly: Cov roj zaub (piv txwv li, cov kua ester-based) yog biodegradable, tsis muaj tshuaj lom, thiab muaj qhov cuam tshuam tsawg dua rau ib puag ncig piv rau cov roj av ib txwm muaj.
Kev Nyab Xeeb Hluav Taws Kub: Cov roj zaub muaj qhov kub hnyiab siab dua, ua rau nws muaj kev nyab xeeb dua yog tias muaj qhov tsis zoo lossis kub dhau.
Cov Khoom Siv Thermal Zoo Kawg Nkaus: Nws muab kev txias thiab rwb thaiv tsev zoo, ua kom ruaj khov thaum muaj kev thauj khoom ntau.
- Muaj Peev Xwm Hluav Taws Xob Siab
1600kVA Kev Ntsuas: Haum rau nruab nrab mus rau loj Kev Faib Fais Fab cov tes hauj lwm, muaj peev xwm tswj tau qhov kev xav tau hluav taws xob siab.
Kev rwb thaiv hluav taws xob siab: Tsim los kom tiv taus kev ntxhov siab ntawm hluav taws xob siab, ua kom muaj kev ua tau zoo hauv cov chaw nyuaj.
- Kev Tsim Kho Ruaj Khov
Cov Core thiab Windings uas ruaj khov: Cov core thiab windings zoo uas sib nqus tau zoo txo qhov poob thiab txhim kho kev ruaj khov.
Lub Tank Uas Tiv Thaiv Kev Kub Ntxhov: Lub tank transformer feem ntau yog ua los ntawm cov khoom siv uas tiv thaiv kev kub ntxhov kom ntseeg tau tias muaj lub neej ntev.
- Lub Tshuab Txias Siab Tshaj Plaws
Kev Tshem Tawm Kub Zoo: Tsim los nrog cov radiators lossis cov fins txias kom tswj tau qhov kub thiab txias zoo tshaj plaws.
Kev Txias Ntuj Los Yog Yuam Kom Txias: Nyob ntawm tus qauv tsim, nws yuav siv cov txheej txheem cua sov ntuj los yog cov txheej txheem txias yuam kom tswj tau cua sov zoo dua.
- Kev Saib Xyuas Tsawg
Kev Pab Cuam Ntev: Cov roj zaub thiab cov khoom siv zoo txo qhov xav tau kev saib xyuas ntau zaus.
Cov Khoom Uas Kho Tau Tus Kheej: Cov roj zaub tuaj yeem pab txo qhov me me ntawm qhov tsis ua haujlwm ntawm lub rwb thaiv tsev, ua rau lub transformer lub neej ntev dua.
- Cov txiaj ntsig ntawm ib puag ncig
Txo Cov Pa roj carbon Footprint: Cov roj zaub yog los ntawm cov peev txheej rov ua dua tshiab, pab txhawb rau kev ruaj khov.
Tsis Muaj Tshuaj Lom thiab Muaj Kev Nyab Xeeb: Tsis zoo li cov roj av, cov roj zaub tsis ua rau muaj kev phom sij rau ib puag ncig lossis tib neeg kev noj qab haus huv yog tias muaj kev xau.
- Kev Saib Xyuas Ntse (Xaiv Tau)
Cov Sensors Sib Koom Ua Ke: Qee cov qauv tuaj nrog cov sensors rau kev saib xyuas lub sijhawm tiag tiag ntawm qhov kub thiab txias, qib roj, thiab cov xwm txheej thauj khoom.
Kev Saib Xyuas Deb: Ua kom muaj kev txij nkawm ua ntej thiab txo lub sijhawm tsis ua haujlwm.
- Tsim Qauv Me Me
Txuag Chaw: Txawm hais tias nws muaj peev xwm siab, lub transformer no tau tsim los kom me me, ua rau nws haum rau kev teeb tsa nrog qhov chaw tsawg.
- Kev Ua Raws Cai thiab Daim Ntawv Pov Thawj
Cov Txheej Txheem Thoob Ntiaj Teb: Ua raws li cov qauv xws li IEC 60076, IEEE C57, thiab lwm yam.
Cov Ntawv Pov Thawj Kev Nyab Xeeb: Ua tau raws li kev nyab xeeb thiab cov cai ib puag ncig, ua kom ntseeg tau tias kev ua haujlwm txhim khu kev qha thiab muaj kev nyab xeeb.
- Cov Kev Xaiv Uas Koj Xav Tau
Kev Ntsuas Voltage: Muaj peev xwm hloov kho kom tau raws li qhov xav tau voltage tshwj xeeb.
Cov Nta Ntxiv: Cov kev xaiv xws li cov kais hloov pauv, cov relays tiv thaiv, thiab cov ntaub thaiv rau kev siv sab nraum zoov.
Cov roj zaub transformer yog ib hom hluav taws xob zoo rau ib puag ncig, muaj kev nyab xeeb thiab siv tau zoo, uas tsim nyog rau ntau lub sijhawm nrog kev xav tau siab rau kev tiv thaiv ib puag ncig thiab kev nyab xeeb. Nws tsis tsuas yog ua tau raws li qhov xav tau ntawm cov tshuab hluav taws xob niaj hnub, tab sis kuj pab txhawb rau kev txhim kho kom ruaj khov.