+86 18068001229 Lub tank transformer - kawm txog cov hom, cov ntaub ntawv, thiab ntau ntxiv!

Cov thawv transformer yog ib qho tseem ceeb tab sis feem ntau tsis quav ntsej txog cov khoom siv hluav taws xob. Cov thawv ruaj khov no ua lub luag haujlwm tseem ceeb hauv kev ua kom ntseeg tau tias kev ua haujlwm ntawm Cov Hloov Fais FabTab sis dab tsi ua rau ntau hom transformer tanks sib txawv, thiab cov ntaub ntawv uas lawv ua los ntawm kev cuam tshuam li cas rau kev ua tau zoo? Nyeem ntxiv kom pom qhov sib txawv tseem ceeb, kev ua haujlwm, thiab cov ntaub ntawv uas ua rau cov tanks no tseem ceeb heev hauv cov kab ke fais fab.
Lub tank transformer yog dab tsi?
Lub thawv transformer yog lub plhaub sab nraud ntawm lub transformer fais fab uas muaj thiab tiv thaiv nws cov khoom sab hauv, xws li lub plawv thiab cov xov hlau. Feem ntau nws yog ua los ntawm hlau thiab ntim nrog roj rwb thaiv tsev, uas ua haujlwm ob lub luag haujlwm tseem ceeb: muab kev rwb thaiv tsev ntawm cov khoom hluav taws xob thiab tshem tawm cov cua sov tsim tawm thaum lub sijhawm ua haujlwm ntawm lub transformer. Lub thawv pab tswj qhov kub ntawm lub transformer los ntawm kev ncig cov roj thiab feem ntau suav nrog cov tshuab cua txias xws li radiators lossis kiv cua. Tsis tas li ntawd, lub thawv raug kaw kom tiv thaiv cov roj xau thiab tiv thaiv cov khoom sab hauv los ntawm cov xwm txheej sab nraud.
Hom ntawm cov tank transformer
Muaj ob hom transformer tank tseem ceeb, txhua tus tsim los kom haum rau cov kev xav tau thiab ib puag ncig ntawm transformer
Lub tank transformer ib txwm muaj
Lub thawv transformer ib txwm muaj (kaw) yog ib lub kaw lus ruaj khov, kaw tag nrho uas muaj roj rwb thaiv tsev, tsim los tiv thaiv cov khoom sab hauv ntawm lub transformer, xws li lub plawv thiab cov xov hlau, los ntawm cov xwm txheej sab nraud xws li dej noo, av qias neeg, thiab huab cua paug. Lub thawv tsim uas kaw cia tso cai rau lub thawv kom tiv taus qhov sib txawv ntawm lub siab uas tshwm sim los ntawm kev hloov pauv kub thaum lub sijhawm ua haujlwm ntawm lub transformer, tswj kev ua haujlwm ntawm roj thiab ua kom muaj kev ua haujlwm ruaj khov. Cov thawv no feem ntau muaj lub tshuab ua pa, feem ntau muaj silica gel, los lim cov dej noo ntawm huab cua ib puag ncig thaum roj nthuav dav lossis cog lus. Lub thawv no siv dav hauv kev faib khoom thiab cov transformers fais fab me me vim nws yooj yim thiab kev ntseeg tau.
Lub tank khaws cia
Ntawm qhov tod tes, lub tank khaws cia yog lub tank roj sab nraud txuas nrog lub tank transformer tseem ceeb, tsim tshwj xeeb los pab txhawb kev hloov pauv ntawm cov roj vim yog thermal nthuav dav thiab kev sib cog lus. Hauv qhov kev tsim no, thaum cov roj transformer kub thiab nthuav dav, cov roj ntau dhau ntws mus rau hauv lub tank khaws cia, thiab thaum cov roj txias thiab sib cog lus, nws ntws rov qab mus rau hauv lub tank tseem ceeb. Lub kaw lus no tiv thaiv cov roj hauv lub tank tseem ceeb kom tsis txhob raug rau huab cua ncaj qha, uas txo qhov kev pheej hmoo ntawm cov dej noo thiab cov pa oxygen uas tuaj yeem ua rau cov roj cov khoom rwb thaiv tsev puas tsuaj. Lub tshuab ua pa silica gel feem ntau siv ua ke nrog lub tank khaws cia kom nqus cov dej noo los ntawm huab cua nkag mus rau hauv lub tank khaws cia thaum cov roj qib hloov pauv. Qhov kev tsim no yog qhov tshwj xeeb tshaj yog rau cov transformers fais fab loj uas kev tswj hwm cov roj ntim yog qhov tseem ceeb rau kev tswj hwm kev ua haujlwm zoo thiab ua kom lub neej ntawm lub transformer ntev dua.
Cov ntaub ntawv ntawm lub tank transformer
Cov tank transformer feem ntau yog ua los ntawm cov hlau tsis muaj zog lossis cov hlau tsis xeb, nyob ntawm daim ntawv thov thiab cov xwm txheej ib puag ncig uas lub transformer yuav ntsib.
Hlau Nyias: Qhov no yog cov khoom siv feem ntau siv rau cov tank transformer vim nws lub zog ruaj khov, kev siv nyiaj tsim nyog, thiab yooj yim tsim. Hlau nyias muaj zog txaus los tiv taus qhov siab sab hauv los ntawm kev nthuav dav thiab kev sib txhuam ntawm cov roj thaum lub sijhawm ua haujlwm ntawm transformer. Nws feem ntau yog coated lossis pleev xim kom tiv thaiv xeb thiab xeb, tshwj xeeb tshaj yog thaum siv rau hauv qhov chaw sab nraum zoov.
Hlau Tsis Xeb: Rau cov transformers uas muab tso rau hauv qhov chaw nyuaj, xws li cov uas raug huab cua hnyav, kev lag luam tshuaj lom neeg, lossis thaj chaw ntug dej hiav txwv, hlau tsis xeb yog siv vim nws tiv taus xeb zoo heev. Nws kuj tseem muaj kev ruaj khov mus sij hawm ntev thiab txo qhov yuav tsum tau saib xyuas rau lub tank transformer.
Qee zaum, cov hlau galvanized lossis txhuas yuav raug siv rau hauv cov qauv tsim tshwj xeeb los txhim kho kev tiv thaiv xeb lossis txo qhov hnyav, txawm hais tias cov ntaub ntawv no tsis tshua muaj ntau dua li cov hlau tsis muaj zog lossis stainless hlau. Cov thoob dej kuj tseem yuav muaj cov txheej tshwj xeeb lossis cov txheej rwb thaiv tsev kom tiv thaiv kev puas tsuaj rau ib puag ncig.
Xaus lus
Qhov kev xaiv ntawm cov tank transformer ib txwm muaj thiab cov tank conservator nyob ntawm qhov xav tau tshwj xeeb ntawm lub transformer thiab nws ib puag ncig. Ob hom no ua lub luag haujlwm tseem ceeb hauv kev tswj hwm kev ua haujlwm ruaj khov, nrog rau cov ntaub ntawv xws li cov hlau tsis muaj zog thiab cov hlau tsis xeb ua rau muaj kev ruaj khov. Kev nkag siab txog cov hom tank thiab cov ntaub ntawv no yog qhov tseem ceeb rau kev xaiv lub tank transformer kom raug rau kev ua haujlwm zoo thiab kev tiv thaiv mus sij hawm ntev.
Ntawm JZP (JIEZOU POWER), peb muaj ntau tshaj 20 xyoo ntawm kev paub txog kev tsim khoom, kev saib xyuas, thiab kev kho cov transformers. Yog tias koj tab tom nrhiav cov khoom lag luam transformer zoo lossis cov neeg koom tes, thov koj xav tiv tauj peb.