Hauv cov ntawv thov transformer nruab nrab thiab siab voltage, cov txheej txheem tswj roj yog qhov tseem ceeb rau kev tiv thaiv ib puag ncig, kev ua raws li txoj cai, thiab kev nyab xeeb ua haujlwm. Ntawm JZP, peb tshwj xeeb hauv kev tsim cov kev daws teeb meem tswj roj uas tsim los rau cov kev xav tau tshwj xeeb ntawm cov transformers kev lag luam thiab cov khoom siv hluav taws xob. Phau ntawv qhia no piav qhia txog cov kev xav tseem ceeb thiab cov txheej txheem rau kev txiav txim siab qhov loj me zoo tshaj plaws ntawm cov txheej txheem tswj roj transformer, xyuas kom meej tias sib haum nrog cov qauv thoob ntiaj teb thiab cov kev xav tau tshwj xeeb ntawm qhov project.

Cov Yam Tseem Ceeb Uas Cuam Tshuam Rau Qhov Loj Ntawm Lub Tshuab Tiv Thaiv

 

Ntim roj Transformer

 

Lub Ntsiab Cai Tseem Ceeb: Lub kaw lus kaw yuav tsum ua kom haum rau 100% ntawm lub peev xwm roj transformer loj tshaj plawsnyob rau hauv cov xwm txheej ib txwm muaj thiab 110% thaum muaj hluav taws kub(xws li dej tua hluav taws thiab nag)

 

Piv txwv kev suav:

 

Ib lub tshuab hluav taws xob 110 kV nrog lub peev xwm roj 30-ton (≈34 m³) xav tau qhov ntim ntawm 37.4 m³(34 m³ × 1.1) kom ua tau raws li cov qauv kev nyab xeeb hluav taws.

 

Cov Cai Siv:

 

GB50060-2008yuav tsum tau ua kom cov txheej txheem tswj hwm rau Transformer Sab Nrauds nrog roj peev xwm ≥1,000 kg yuav tsum tuav60% ntawm lub tank loj tshaj plawsyog tias muaj kev sib cais roj-dej.

 

Cov Xwm Txheej Tshwj Xeeb ntawm Qhov Chaw

 

 

Kev Teeb Tsa Sab Hauv Tsev vs. Sab Nraud:

 

Cov hloov pauv sab hauv tsev (piv txwv li, hauv cov chaw hloov pauv) feem ntau xav tau kev tswj hwm me dua vim yog qhov chaw tswj hwm, thaum cov kab ke sab nraum zoov yuav tsum suav nrog nag thiab av permeability.

 

Kev Tso Cai Rau Kev Nyab Xeeb Hluav Taws:

 

Tswj ib qho qhov tsawg kawg nkaus 1.5-meter nrugnruab nrab ntawm cov transformers thiab cov phab ntsa uas kub hnyiab tau, thiab 1 meter dhau ntawm cov npoo ntawm transformerrau kev faib dej hluav taws

 

Cov Yam Ntxim Saib Txog Geotechnical thiab Ib puag ncig

 

Peev Xwm Nqa AvSoj ntsuam hom av (piv txwv li, av nplaum, xuab zeb) kom paub tseeb tias lub hauv paus ruaj khov thiab cov dej ntws yuav tsum tau ntws li cas

 

Kev Nag Los NtauRau cov tshuab sab nraum zoov, xam cov dej nag los ntawm kev siv cov ntaub ntawv huab cua hauv zos (piv txwv li, 100 mm/teev rau thaj chaw sov).

 

 

Cov Kauj Ruam Los Ntawm Kauj Ruam Kev Ntsuas Qhov Loj

 

Txheeb Xyuas Qhov Ntim Roj Siab Tshaj Plaws

 

Tshuaj xyuas cov duab kos ntawm lub transformer kom paub qhov muaj peev xwm roj ntau tshaj plaws (piv txwv li, 10,000 litres rau 60 MVA unit).

 

Siv Cov Kev Cai Lij Choj

 

Kev Ua Raws Cai ntawm SPCCRau cov chaw teeb tsa hauv Tebchaws Meskas, ua raws li EPA txoj cai 110% (roj ntau + 10% freeboard)

 

Cov Qauv Suav:

 

GB50053-2013Yuav tsum tau muaj 20% kev tswj rau cov transformers sab hauv tsev uas muaj roj ≥100 kg, nce mus txog 100% yog tias kev ntws dej tsis yooj yim.

 

Xam Qhov Ntim Khoom

 

Cov mis:

 

Nyob rau hauvtag nrho = (Nyob rau hauvroj ×1.1)+(Nyob rau hauvdej × 0.35)

 

V_dej: Qhov ntim dej hluav taws (cheeb tsam saum npoo × tus nqi ntws × lub sijhawm).

 

0.35: Feem pua ​​ntawm cov xuab zeb uas muaj cov pob zeb puv (40% porosity)

 

Tsim rau Ntau Lub Transformers

 

 

Ua kom cov roj ntau ntxiv rau cov transformers clustered thiab ntxiv 20% ​​​​qhov rov ua dua rau kev nthuav dav yav tom ntej.

 

 

Cov Kev Xyaum Zoo Tshaj Plaws rau Kev Tsim Qauv Kev Tswj Xyuas

 

Kev Xaiv Khoom Siv

 

Cov Pob Zeb Ua Los Ntawm Cov Hlau: Nyiam siv rau sab hauv tsev vim nws tiv taus hluav taws thiab ruaj khov.

 

Cov ntaub ntawv GeomembraneSiv cov HDPE liners rau sab nraum zoov kom tiv thaiv kev xau rau hauv av

 

Cov Lus Qhia Txog Txheej Pob Zeb

 

Qhov tuab: ≥250 hli.

 

Qhov Loj ntawm Pob Zeb: 50–80 hli txoj kab uas hla rau qhov zoo tshaj plaws porosity thiab txo hluav taws kub

 

Kev ntws dej thiab kev sib cais roj-dej

 

 

Nruab cov kav dej uas muaj qhov loj ≥150 hli thiab cov ntxaij vab tshaus hlau tsis xeb kom lim cov pa phem.

 

Kev Tiv Thaiv Av Qeeg thiab Cua

 

Tsim cov anchor bolts kom tiv taus 0.4 coefficient ntawm kev sib txhuam zoo li qubthiab cov khoom thauj tshwj xeeb rau thaj chaw seismic

 

 

Xaus lus

Kev xaiv qhov loj ntawm cov roj transformer kom raug yuav tsum tau ua tib zoo saib xyuas cov roj, cov cai tswjfwm, thiab cov xwm txheej ntawm qhov chaw. Ntawm JZP, peb siv cov cuab yeej engineering siab heev thiab cov kev coj ua zoo tshaj plaws hauv kev lag luam los xa cov txheej txheem tswj hwm uas muab qhov tseem ceeb rau kev nyab xeeb, kev ua raws li txoj cai, thiab kev ua haujlwm zoo. Koom tes nrog peb kom ntseeg tau tias koj qhov nruab nrab thiab siab-Cov Hloov Fais Fab Voltage raug tiv thaiv los ntawm kev xau, hluav taws, thiab kev pheej hmoo ib puag ncig.