+86 18068001229 Kev Tshawb Fawb Txog Kev Hloov Pauv ntawm High Voltage Transformer Winding
JZP Transformer Solutions
- Kev Taw Qhia
Winding deformation nyob rau hauv high-Cov Hloov Fais Fab Voltage yog qhov kev txhawj xeeb tseem ceeb txog kev nyab xeeb, feem ntau yog los ntawm kev ntxhov siab ntawm lub tshuab, kev hloov pauv cua sov, lossis kev cuam tshuam luv luv. Ua tus thawj coj hauv kev tsim khoom siv transformer, JZP ua raws li DL / T 1093-2018 Tus Qauv rau Reactance Txoj Kev hauv Winding Deformation Detection thiab koom ua ke cov thev naus laus zis siab heev kom ntseeg tau tias ua raws li thiab kev ntseeg tau. Daim ntawv no piav qhia txog JZP cov lus qhia txog kev siv tshuab rau kev kuaj xyuas kev hloov pauv ntawm winding, uas suav nrog cov txheej txheem, cov khoom siv xav tau, thiab cov txheej txheem ua haujlwm.
- Scope
Cov lus qhia no siv rau:
Qhov hluav taws xob ntau: 35 kV thiab siab dua.
Hom Transformer: Peb theem thiab ib theem Cov Hloov Fais Fab nrog cov qauv concentric winding.
Cov xwm txheej kuaj pom: Kev lees txais los ntawm lub Hoobkas, kev tshuaj xyuas tom qab kev thauj mus los, thiab kev ntsuam xyuas cov xwm txheej tom qab luv luv.
- Cov Txheej Txheem Tshawb Nrhiav Tseem Ceeb
3.1 Txoj Kev Ua Haujlwm Reactance (DL/T 1093-2018 Ua Raws Cai)
Lub Ntsiab Cai: Ntsuas cov kev hloov pauv hauv winding reactance (impedance) nyob rau hauv AC voltage kom pom cov kev cuam tshuam ntawm cov khoom siv.
Cov Ntsiab Lus Tseem Ceeb:
Zaus ntau yam: 10 Hz – 1 MHz.
Qhov tseeb: ± 0.5% rau cov nqi impedance.
Kev ntsuas hluav taws xob: ≤2 kV (AC).
Cov Zoo: Muaj kev nkag siab zoo rau cov kev hloov pauv me me (piv txwv li, 0.1% impedance deviation qhia txog cov teeb meem uas yuav tshwm sim).
3.2 Kev Tshuaj Xyuas Zaus (FRA)
Txoj Kev Tshawb Fawb: Tshawb nrhiav cov zaus ntawm 10 Hz txog 20 MHz kom ntes tau cov yam ntxwv ntawm kev sib hloov ntawm lub zog.
Kev txhim kho ntawm JZP:
Kev kuaj xyuas qhov kev daws teeb meem siab: 50,000 cov ntsiab lus ntaub ntawv rau kev tshuaj xyuas cov duab nthwv dej kom meej.
Kev tsim qauv tiv thaiv kev cuam tshuam: Kev rho tawm qhov muag thiab kev tiv thaiv kom txo tau suab nrov electromagnetic.
Cov zis: Kev tshuaj xyuas sib piv ntawm cov zaus spectra keeb kwm piv rau tam sim no los txheeb xyuas qhov hloov pauv ntawm cov resonance peaks (piv txwv li, >3 dB variation ua rau muaj kev ceeb toom).
- Cov Kev Cai Txuj Ci
- Cov Txheej Txheem Kev Xeem
5.1 Kev Npaj Ua Ntej Kev Xeem
Kev kuaj xyuas cov khoom siv: Xyuas kom tseeb tias qhov kev ntsuas qhov ntsuas ntawm lub sensor (piv txwv li, Rogowski coils rau cov teeb liab zaus siab).
Lub xeev transformer: Xyuas kom tseeb tias lub transformer tsis muaj zog thiab tau grounded.
5.2 Kev Ua Haujlwm Sim
Kev teeb tsa xov hlau:
Lub kauj hluav taws xob thawj zaug: Siv lub teeb liab sim (piv txwv li, lub zog hloov pauv los ntawm qhov qhib ntawm lub tshuab hluav taws xob).
Cov xov hluav taws xob thib ob: Txuas cov sensors los ntsuas cov teeb liab uas tau tshwm sim.
Kev teeb tsa parameter:
Cov kauj ruam luam theej zaus: Kev faib tawm Logarithmic rau kev them tag nrho.
Qhov txwv ntawm kev ua kom lub zog ua haujlwm: Kho kom raug raws li lub peev xwm ntawm lub transformer (piv txwv li, 110 kV transformers xav tau 100 × qhov rhiab heev).
Kev tau txais cov ntaub ntawv:
Ntes tau 200+ cov qauv ib qho zaus.
Cov zaub tiag tiag ntawm qhov loj ntawm impedance / theem kaum sab xis.
5.3 Kev Tshuaj Xyuas Tom Qab Kev Xeem
Kev kuaj mob tsis siv neeg:
Piv rau lub hauv paus ntawm lub Hoobkas (piv txwv li, impedance deviation >2% qhia txog kev hloov pauv).
3D daim ntawv qhia ntawm kev faib tawm ntawm kev ntxhov siab winding.
Kev Tshaj Tawm: Tsim cov ntawv tshaj tawm kev ua raws cai nrog cov duab thiab cov lus qhia ua tau.
- Kev Kawm Txog Qhov Teeb Meem: Lub Tshuab Hloov Pauv Cua
Xwm txheej: Lub tshuab hluav taws xob cua 33 kV tau pom tias muaj 15% impedance deviation tom qab cua daj cua dub.
JZP txoj kev daws teeb meem:
Ua qhov kev sim FRA, qhia txog 4 kHz resonance peak shift.
Txheeb xyuas qhov kev hloov pauv ntawm ib feem ntawm cov winding los ntawm 3D thermal imaging.
Pom zoo kom rov ua dua, tiv thaiv kev ua tsis tiav loj heev.
- Kev Ua Raws Cai & Daim Ntawv Pov Thawj
Cov qauv thoob ntiaj teb: IEC 60076-18, IEEE C57.152.
Daim Ntawv Pov Thawj: CE, UL, ISO 9001.
Kev lees paub los ntawm sab nraud: Kev tshuaj xyuas txhua xyoo los ntawm TÜV Rheinland.
- Xaus lus
JZP lub tshuab nrhiav kev hloov pauv ntawm lub winding ua ke kev ntsuas qhov tseeb, kev tshuaj xyuas AI, thiab kev ua raws li DL/T 1093-2018 tag nrho. Los ntawm kev koom ua ke cov thev naus laus zis tshiab xws li FRA zaus siab thiab kev tshaj tawm tsis siv neeg, peb ua kom cov transformers ua haujlwm tau zoo thiab muaj kev nyab xeeb thoob plaws cov haujlwm thoob ntiaj teb.