Kev Taw Qhia
Kev thawb kom txo cov pa roj carbon thoob ntiaj teb tau mus txog txhua lub ces kaum ntawm kev lag luam hluav taws xob - suav nrog lub transformer uas tsis muaj zog. Tau ntau xyoo, cov thev naus laus zis transformer tseem tsis hloov pauv: roj av rau kev rwb thaiv tsev, hlau ua los ntawm cov noob rau cov cores, thiab cov qib kev ua haujlwm uas tsuas yog txhim kho me ntsis xwb.
Niaj hnub no, qhov xwm txheej ntawd tab tom hloov pauv sai heev. Nrog rau kev poob ntawm cov transformer suav txog kwv yees li 2 txog 3 feem pua ntawm kev tsim hluav taws xob thoob ntiaj teb, lub peev xwm rau kev txo cov pa phem los ntawm kev tsim qauv zoo dua yog qhov tseem ceeb. Lub caij no, kev loj hlob ntawm cov cai ib puag ncig thiab cov hom phiaj kev ruaj khov ntawm cov tuam txhab tab tom thawb cov chaw tsim khoom thiab cov chaw muab kev pabcuam kom rov xav txog txhua yam ntawm kev tsim cov transformer - los ntawm cov kua uas lawv muaj mus rau cov ntaub ntawv uas lawv tau tsim.
Tsab xov xwm no tshuaj xyuas ob txoj hauv kev tseem ceeb tshaj plaws rau kev siv cov transformers uas ntsuab dua: cov kua dej rwb thaiv tsev ntuj thiab cov hlau amorphous cores. Ua ke, cov kev tsim kho tshiab no tau txhais dua qhov nws txhais li cas rau lub transformer kom "ntsuab."
Tshooj Ib: Txhais lub Transformer Ntsuab
Dab tsi ua rau lub transformer "ntsuab"? Cov lus teb nthuav dav tshaj qhov ntsuas kev ua haujlwm yooj yim.
Ib lub tshuab hloov pauv ntsuab tiag tiag xav txog qhov cuam tshuam rau ib puag ncig thoob plaws nws lub neej tag nrho - txij li kev rho tawm cov khoom siv raw mus txog kev tsim khoom, kev ua haujlwm, thiab thaum kawg pov tseg lossis rov ua dua tshiab. Cov yam ntxwv tseem ceeb suav nrog:
- Txo cov kev poob haujlwm, txo cov kev pov tseg hluav taws xob ntau xyoo dhau los ntawm kev pabcuam
- Cov kua dej rwb thaiv tsev uas lwj tau, tshem tawm kev puas tsuaj rau ib puag ncig mus sij hawm ntev los ntawm kev xau
- Kev pheej hmoo hluav taws tsawg dua, txhim kho kev nyab xeeb rau cov zej zog nyob ib puag ncig
- Txo cov khoom siv zog, txuag cov peev txheej thaum lub sijhawm tsim khoom
- Kev siv rov qab tau, xyuas kom meej tias cov khoom siv uas siv tas mus li tuaj yeem rov qab tau
Kev ua lag luam rau cov khoom siv zoo li no tab tom loj hlob zuj zus. Raws li kev tshawb fawb kev lag luam, kev ua lag luam thoob ntiaj teb rau kev siv hluav taws xob ntsuab Cov Hloov Fais Fab tau muaj nqis kwv yees li $ 10.9 billion hauv xyoo 2024 thiab kwv yees tias yuav ncav cuag $ 14.1 billion los ntawm xyoo 2030. Lwm txoj kev tshawb fawb tso lub lag luam thoob ntiaj teb xyoo 2025 rau cov transformers uas tsis muaj kuab paug rau ib puag ncig ntawm kwv yees li $ 13.13 billion, nrog rau kev loj hlob txhua xyoo ntawm 6.5 feem pua txog xyoo 2032.
Txoj kev loj hlob no yog tsav los ntawm ntau yam: kev nthuav dav zog rov ua dua tshiab, cov kev pab cuam niaj hnub ntawm lub grid, cov qauv kev ua haujlwm zoo dua, thiab kev paub ntau ntxiv txog kev pheej hmoo ib puag ncig uas cuam tshuam nrog cov thev naus laus zis transformer ib txwm muaj.
Tshooj Ob: Kev Hloov Pauv Dej - Cov Esters Ntuj
Tau ntau tshaj ib puas xyoo, cov roj av tau yog cov khoom siv rwb thaiv tsev thiab txias rau cov transformers uas muaj kua. Nws muaj txiaj ntsig zoo, nkag siab zoo, thiab pheej yig - tab sis nws muaj qhov tsis zoo. Cov roj av qeeb qeeb lwj tau zoo tshaj plaws, muaj kev pheej hmoo hluav taws vim nws qhov kub qis (feem ntau yog 160-180 ° C), thiab tuaj yeem ua rau muaj kev puas tsuaj rau ib puag ncig mus sij hawm ntev yog tias xau.
Cov kua ester ntuj tsim—uas tau los ntawm cov roj zaub xws li taum pauv lossis rapeseed—muab lwm txoj hauv kev zoo heev.
Kev Sib Haum Xeeb Ib puag ncig.Cov esters ntuj tsim tau yooj yim lwj, ua tiav cov nqi lwj ntawm 95 feem pua lossis siab dua hauv ob peb lub lis piam hauv cov xwm txheej sim txheem. Qhov no ua rau lawv tsim nyog tshwj xeeb rau cov chaw uas muaj kev cuam tshuam rau ib puag ncig - ze ntawm cov dej ntws, hauv cov cheeb tsam ntuj tsim, lossis hauv cov chaw hauv nroog uas cov khoom siv tswj hwm tsawg. Yog tias muaj qhov xau, qhov cuam tshuam rau ib puag ncig raug txo qis ntau dua li cov roj av.
Kev Nyab Xeeb Hluav Taws.Cov txiaj ntsig kev nyab xeeb ntawm cov esters ntuj kuj tseem ceeb ib yam nkaus. Nrog rau qhov kub siab tshaj 300 ° C - feem ntau ncav cuag 350 ° C lossis siab dua - cov kua no txo qhov kev pheej hmoo hluav taws kub heev. Qee cov qauv ua rau pom cov khoom tua tus kheej, muab ib txheej ntxiv ntawm kev tiv thaiv. Rau kev teeb tsa sab hauv tsev lossis thaj chaw muaj neeg coob coob, qhov cwj pwm no ib leeg tuaj yeem ua pov thawj xaiv cov transformers ester-filled ntuj.
Kev Ua Tau Zoo.Tsis tas li ntawm kev nyab xeeb thiab cov txiaj ntsig ib puag ncig, cov esters ntuj tsim muaj cov txiaj ntsig zoo rau kev siv tshuab. Cov kua dej ua kom noo noo ntau dua pab ua kom lub neej rwb thaiv tsev ntev dua, vim tias daim ntawv cellulose uas muaj cov ester ntuj tsim lwj qeeb dua li cov roj av hauv cov xwm txheej zoo sib xws. Cov esters ntuj tsim kuj ua rau muaj kev ruaj khov zoo heev thaum tsim cov tshuaj kom raug, ua rau lub sijhawm ua haujlwm ntev dua.
Kev Pom Zoo Hauv Lub Ntiaj Teb Tiag.Cov thev naus laus zis no tsis yog kev sim lawm. Raws li cov ntaub ntawv hauv kev lag luam, muaj ntau tshaj ob lab lub tshuab hluav taws xob ester ntuj tam sim no ua haujlwm thoob ntiaj teb. Cov theem hluav taws xob tau nce siab zuj zus thaum kev ntseeg siab loj hlob tuaj - Hitachi Energy nyuam qhuav tau txais daim ntawv pov thawj kev tshaj lij rau 765 kV, 250 MVA lub tshuab hluav taws xob ester ntuj, qhov chaw muaj hluav taws xob siab tshaj plaws ntawm nws hom. Hauv Asia, cov chaw tsim khoom tau ua tiav xa cov tshuab hluav taws xob amorphous hlau uas muaj ester ntuj mus rau Nyiv Pooj, qhov chaw uas lawv tam sim no ua haujlwm hauv lub grid.
Tshooj Peb: Kev Tshawb Fawb Tseem Ceeb - Amorphous Hlau
Thaum cov esters ntuj tsim teb raug hais txog qhov ib puag ncig thiab kev nyab xeeb ntawm kev ua haujlwm ntawm transformer, cov hlau amorphous cores daws qhov teeb meem tseem ceeb ntawm kev siv hluav taws xob zoo.
Kev Tshawb Fawb Txog Khoom Siv.Cov hlau transformer cores ib txwm muaj yog tsim los ntawm cov hlau silicon uas muaj cov noob, uas yog cov khoom siv crystalline uas muaj cov qauv atomic. Cov hlau amorphous yog tsim los ntawm kev txias cov hlau molten sai heev - ntawm tus nqi ze li ib lab degrees ib ob - uas crystallization tsis tshwm sim. Cov khoom khov kho khaws cia qhov kev npaj atomic random ntawm cov kua theem.
Cov qauv tsis sib haum xeeb no muaj feem cuam tshuam loj heev rau tus cwj pwm sib nqus. Hauv cov ntaub ntawv crystalline, cov chaw sib nqus yuav tsum sib phim nrog cov lus qhia crystallographic tshwj xeeb, xav tau lub zog nkag nrog txhua lub voj voog tam sim no hloov pauv. Hauv cov hlau amorphous, qhov tsis muaj kev txiav txim crystalline tso cai rau cov chaw teb tau yooj yim dua rau kev hloov pauv ntawm cov teb sib nqus. Qhov tshwm sim yog qhov txo qis hauv kev poob hysteresis - lub zog dissipated txhua lub sijhawm lub hauv paus yog magnetized thiab demagnetized.
Cov Txiaj Ntsig Uas Ntsuas Tau.Qhov kev txhim kho kev ua tau zoo yog qhov tseem ceeb. Cov hlau amorphous cores txo qhov poob tsis muaj load los ntawm kwv yees li 70 txog 80 feem pua piv rau cov hlau uas muaj cov noob qoob loo. Rau ib qho 1,000 kVA ib txwm muaj Kev Hloov Pauv Hloov Chaw, qhov no txhais tau tias kev txuag hluav taws xob txhua xyoo tshaj 6,000 kWh. Tshaj li 30 xyoo kev pabcuam lub neej, qhov kev txo qis ntawm CO₂ emissions tuaj yeem ncav cuag kwv yees li 4,400 tons ib lub transformer.
Cov Kev Xav Txog Daim Ntawv Thov.Cov hlau hloov pauv uas tsis muaj duab zoo sib xws kuj muaj ntau yam sib txawv. Cov khoom siv kim dua li cov hlau ib txwm muaj, thiab nws cov khoom siv sib nqus xav tau cov qauv tsim sib txawv. Cov hloov pauv yuav loj dua thiab hnyav dua rau qhov ntsuas, uas tuaj yeem tsim teeb meem rau kev teeb tsa hauv cov chaw uas muaj qhov chaw txwv. Txawm li cas los xij, rau cov ntawv thov uas tsis muaj kev poob siab - xws li cov hloov pauv faib khoom uas muaj lub zog me me feem ntau - qhov zoo ntawm tus nqi siv tau yog qhov tseeb.
Kev tshuaj xyuas kev lag luam lees paub tias txawm tias tus nqi pib siab dua, cov hlau hloov pauv amorphous muab tus nqi qis dua ntawm kev muaj thaum kev poob raug ntsuas kom raug. Qhov no yog qhov tseeb tshwj xeeb hauv kev lag luam uas muaj tus nqi hluav taws xob siab lossis cov qauv kev ua haujlwm zoo.
Tshooj Plaub: Txoj Kev Sib Koom Tes—Kev Sib Koom Tes Hauv Kev Tsim Qauv
Cov transformers ntsuab tshiab tshaj plaws muab ob qho kev tsim kho tshiab: kev rwb thaiv tsev ester ntuj thiab cov hlau amorphous cores. Txoj hauv kev ob no daws qhov cuam tshuam rau ib puag ncig los ntawm txhua lub kaum sab xis.
Ib qho piv txwv tiag tiag hauv ntiaj teb.Ib lub tshuab hluav taws xob faib hluav taws xob uas tsim los ntawm cov hlau tsis muaj zog thiab roj ester ntuj tau ua pov thawj tias txo qhov kev poob qis thaum ua tau raws li txhua tus qauv kev siv tshuab. Kev sib xyaw ua ke tau ua pov thawj tias muaj txiaj ntsig zoo thiab muaj txiaj ntsig zoo thaum ntsuas tus nqi tag nrho ntawm kev muaj.
Tshaj Qhov Core thiab Fluid.Lwm yam kev tsim kho tshiab ua kom tiav cov thev naus laus zis tseem ceeb no. Cov hlau silicon uas nyias nyias - txog li 0.20 hli tuab - muab kev ua tau zoo dua thaum tswj cov txheej txheem tsim khoom zoo. Rau cov ntawv thov uas tsis yooj yim rau kev rwb thaiv tsev kua, Transformer Hom Qhuavs nrog epoxy-encapsulated windings muab hluav taws-nyab xeeb, tsis muaj to. Thiab rau cov theem voltage siab tshaj plaws, kev tshawb fawb txuas ntxiv mus rau hauv ester-compatible insulation systems txuas ntxiv thawb cov ciam teb ntawm qhov ua tau.
Cov Kev Xaiv Tshiab.Rau cov ntawv thov tshwj xeeb, cov roj-insulated transformers siv C₄F₇N/CO₂ sib xyaws muab lwm txoj hauv kev los txo qhov cuam tshuam rau ib puag ncig, ua ke tsis muaj hluav taws kub nrog qhov qis dua qhov ua kom sov thoob ntiaj teb dua li cov SF₆-insulated ib txwm muaj.
Tshooj Tsib: Kev Lag Luam thiab Kev Siv Cov Khoom Siv
Kev hloov mus rau cov hloov pauv ntsuab tab tom nrawm dua, tsav los ntawm ntau lub zog.
Kev Tswj Xyuas Siab.Cov qauv kev ua haujlwm zoo thoob ntiaj teb tab tom ua nruj dua. Tuam Tshoj tus qauv GB 20052-2020, EU cov cai Ecodesign, thiab cov qauv zoo sib xws hauv lwm lub khw tau yuam kom muaj cov qib ua haujlwm zoo dua uas nyiam cov hlau amorphous thiab lwm yam khoom siv tseem ceeb. Cov cai kev nyab xeeb hluav taws txwv tsis pub muaj cov roj av hauv cov cheeb tsam uas muaj neeg coob coob, ua rau muaj kev thov rau lwm cov ester ntuj.
Lub Hom Phiaj Kev Ruaj Ntseg ntawm Lub Tuam Txhab.Cov chaw muab kev pabcuam thiab cov neeg siv khoom lag luam loj tab tom raug kev nyuaj siab kom txo lawv cov pa roj carbon dioxide. Cov kev hloov pauv ntsuab muab txoj hauv kev los qhia txog kev cog lus rau ib puag ncig thaum txo cov nqi ua haujlwm. Qee tus neeg yuav khoom tam sim no xav tau Cov Lus Tshaj Tawm Txog Khoom Siv Ib puag ncig lossis daim ntawv pov thawj carbon dioxide ua ib feem ntawm cov lus qhia txog kev yuav khoom.
Kev Sib Tw Nqi.Thaum cov khoom tsim tawm ntau ntxiv thiab kev paub txog kev tsim khoom ntau ntxiv, tus nqi them rau cov transformers ntsuab tab tom poob qis. Rau ntau daim ntawv thov, qhov zoo ntawm lub neej voj voog tam sim no nyiam cov kev xaiv ntsuab dua txawm tias tsis xav txog cov txiaj ntsig ib puag ncig.
Xaus Lus: Txoj Kev Mus Tom Ntej Kom Meej
Lo lus nug "Puas yog cov transformers tuaj yeem ua ntsuab tiag tiag?" muaj lus teb meej: lawv twb yog lawm, thiab cov thev naus laus zis txuas ntxiv txhim kho.
Cov kua ester ntuj tsim tshem tawm cov kev txhawj xeeb txog kev nyab xeeb ib puag ncig thiab hluav taws uas cuam tshuam nrog cov roj av thaum muab kev ua haujlwm zoo sib xws lossis zoo dua. Cov hlau amorphous cores txo qhov poob thaum tsis muaj kev thauj khoom los ntawm 70 txog 80 feem pua, xa cov kev txuag hluav taws xob ntau dhau ntau xyoo ntawm kev ua haujlwm. Ua ke, cov thev naus laus zis no txhais tau tias yog tiam tshiab ntawm cov transformers uas muaj kev nyab xeeb dua, huv dua, thiab ua haujlwm tau zoo dua li txhua yam uas tau los ua ntej.
Rau cov kws tshaj lij kev yuav khoom thiab cov neeg tsim kho qhov project, qhov cuam tshuam yog qhov yooj yim. Cov transformers ntsuab tsis yog cov khoom lag luam tshwj xeeb lossis cov qauv sim. Lawv muaj nyob rau hauv kev lag luam, tau lees paub tias yog technology, thiab pheej yig dua. Kev qhia meej txog lawv hnub no txhais tau tias cov nqi khiav lag luam qis dua, txo qis kev pheej hmoo ib puag ncig, thiab sib haum nrog kev thawb thoob ntiaj teb mus rau yav tom ntej ntawm lub zog hluav taws xob uas ruaj khov dua.
Lub transformer tau raug hu ua lub zog ua haujlwm ntawm lub grid hluav taws xob. Nrog rau cov kev tsim kho tshiab no, nws tab tom dhau los ua ntau yam ntxiv: tus neeg pab txhawb rau kev hloov pauv lub zog huv.